![Banner Sure Cross DXM700-B Series Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/banner/sure-cross-dxm700-b-series/sure-cross-dxm700-b-series_instruction-manual_471859028.webp)
Modbus Registers for Virtual Registers
Registers
Definition
10057–10058
Alarms, smtp, fails
Email failures
10100
Number of read maps in default
Read Map statistics
10101
Number of read map successes
10102
Number of read map timeouts
10103
Number of read map errors
10104
Read map success streak
10105
Number of write map successes
Write Map statistics
10106
Number of write map timeouts
10107
Number of write map errors
10108
Write map success streak
10109
Number of passthrough successes
API message passing statistics
10110
Number of passthrough timeouts
10111
Number of passthrough errors
10112
Passthrough success streak
10113
Number of 43 buffer successes
DX80 Gateway automatic messaging buffer statistics
10114
Number of 43 buffer timeouts
10115
Number of 43 buffer errors
10116
43 buffer success streak
11000
Read map success count
Read/Write maps statistics
12000
Write map success count
13000
Read map timeout count
14000
Write map timeout count
15000
Read map error count
16000
Write map error count
17000
Read map success streak
18000
Write map success streak
19000
Read map is in default
TCP Client Stats—The "x" represents the socket 0 through 4. The flex socket is not used. This range repeats for the next
socket.
TCP Client Stats
Register
Definition
2x001
Socket x connection attempts (20001 is the first socket, 21001 is the second socket...)
2x003
Socket x connections
2x005
Socket x disconnections
2x007
Socket x transmits
2x009
Socket x receives
2x011
Socket x resolver attempts (reserved)
2x013
Socket x resolvers (reserved)
Sure Cross
®
DXM700-Bx Wireless Controller
28
www.bannerengineering.com - Tel: + 1 888 373 6767