3. Trigger the sensor.
>>
do trigger
\x0D\x0A
<<
OK\x0D\x0A
4. Check that the inspection passed.
>>
get inspection status
\x0D\x0A
<<
OK\x0D\x0A
<<
Pass\x0D\x0A
5. Get the barcode data read by the iVu sensor.
>>
get bcr_result data
\x0D\x0A
<<
OK\x0D\x0A
<<
"0043000011201"\x0D\x0A
3.4 iVu Plus Command Channel Reference
3.4 Info Command Group
Command
Group
Item
Description
Get
Info
CompanyName
The company name as a string.
Get
Info
ModelNumber
The sensor model number as a
string.
Get
Info
FirmwareVersion
The sensor firmware version as
a string.
Get
Info
SerialNumber
The sensor serial number as a
string.
Get
Info
Name
The sensor name as a string.
Get
Info
BootNumber
The number of sensor bootups
Get
Info
UpTimer
The elapsed time the sensor
has been running in the format
hh:mm:ss:msec.
Get
Info
HourCount
The number of hours the sensor
has been running.
Get
Info
RemoteConnected
The remote display connected
status as a boolean value (true
or false)
Get
Info
RemoteModelNumber
The model number of the re-
mote display as a string.
Get
Info
RemoteSerialNumber
The serial number of the remote
display as a string.
iVu Plus BCR Communications User's Guide
24
www.bannerengineering.com - tel: 763-544-3164