Command
Group
Item
Description
Get
Inspection
Name
The name of the active inspec-
tion.
Get
Inspection
FrameNumber
The most recent inspection
frame number
Get
Inspection
ExecutionTime
The most recent inspection exe-
cution time in msec.
Examples
>>
get inspection status
\x0D\x0A
<<
OK\x0D\x0A
<<
Fail\x0D\x0A
>>
get inspection executiontime
\x0D\x0A
<<
OK\x0D\x0A
<<
37.739\x0D\x0A
3.4 BCR_INPUT Command Group
Command
Group
Item
Description
Get
BCR_INPUT
CompareData
The Barcode inspection com-
pare data string. This string
must start and end with the dou-
ble quote character. This value
can be modified using the sen-
sor's touchscreen. This remote-
ly modified value is not persis-
ted to the sensors permanent
memory. The 'Save' operation is
required to persist this value.
Set
BCR_INPUT
CompareData
The Barcode inspection com-
pare data string. This string
must start and end with the dou-
ble quote character. This value
can be modified using the sen-
sor's touchscreen. This remote-
ly modified value is not persis-
ted to the sensors permanent
memory. The 'Save' operation is
required to persist this value.
Get
BCR_INPUT
CompareMask
The Barcode inspection com-
pare string mask in binary for-
mat; that is, masked characters
are indicated by a "1" and un-
masked characters are "0."
Note that the mask character
string must match the length of
the compare string. This value
iVu Plus BCR Communications User's Guide