![Banner iVu Plus Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/banner/ivu-plus/ivu-plus_user-manual_3759257005.webp)
1.1.3 Sample Application
The iVu Plus BCR installation CD has a Data Export sample application that provides for viewing exported data while setting up the
sensor, etc. In a production environment, you will need to create your own application to process data exported from the sensor.
1.1.4 Image Export
Image export is only supported on Ethernet ports. Inspection images are a maximum 8-bits per pixel grayscale images in Windows BMP
format that represent all the data in a full Field of View (FOV).
Each exported image is comprised of a header (64 bytes) followed by the image data (approximately ). All 16- and 32-bit numeric entries
are little endian.
The header includes the following information:
NOTE: If FOV's are adjusted so that they are smaller, the bitmaps will also be smaller.
1.1.4 Image Export Sample Application
The iVu Plus BCR installation CD has a Image Export sample application that provides a way to save exported images. In a production
environment, you will need to write your own application to process exported images, for example to display them on an HMI or to save
them to disk.
iVu Plus BCR Communications User's Guide
Online Only - rev. A
www.bannerengineering.com - tel: 763-544-3164
5