3.4 BCR_HISTORY Command Group
Command
Group
Item
Description
Get
BCR_HISTORY
MinCount
This value indicates the mini-
mum number of barcodes read
for the active inspection This
value is cleared (reset) whenev-
er history is cleared. This value
is cleared (reset) when the de-
vice starts up or is rebooted.
Get
BCR_HISTORY
MaxCount
This value indicates the maxi-
mum number of barcodes read
for the active inspection This
value is cleared (reset) whenev-
er history is cleared. This value
is cleared (reset) when the de-
vice starts up or is rebooted.
Examples
3.5 Command Channel Error Codes
Numeric ID
Text ID
Description
00000
SUCCESS
Command processed successfully
10000
EMPTY_FRAME_RECEIVED
Indicates that the request was empty. The
command channel requires a command,
any arguments, and an end-of-frame delim-
iter.
10001
COMMAND_NOT_RECOGNIZED
The command specified is not recognized
10100
GROUP_MISSING
A Group ID must be specified immediately
after the command
10101
GROUP_NOT_FOUND
The specified Group ID is invalid / unknown
10102
GROUP_ITEM_MISSING
A Group Item ID must be specified immedi-
ately after the Group ID
10103
GROUP_ITEM_NOT_FOUND
The specified Group Item ID is invalid / un-
known
10152
NOT_READABLE
Attempt to get a value that is not readable
10153
NOT_WRITEABLE
Attempt to set a value that is not writeable
10250
NOT_A_METHOD
Method ID specified is not a method
10251
WRONG_ARGUMENT_COUNT
Total method arguments specified do not
match method
10252
COMMAND_NOT_FINISHED
Attempt to issue command when a previous
command has not finished
10300
INVALID_ARGUMENT_TYPE
Item ID specified must be a item (not a
group or method)
iVu Plus BCR Communications User's Guide
Online Only - rev. A
www.bannerengineering.com - tel: 763-544-3164
33