5.4.7 ProductChange Command Group
Command
Group
Item
Description
Do
ProductChange
[Name]
Forces the sensor to switch to the specified inspection. The sensor does
not transmit a response until the sensor has completed the action.
Inspections results will be invalid until the next trigger.
Get
ProductChange
InspectionNames
List of all inspections stored in the sensor.
Examples
>>
get productchange inspectionnames
\x0D\x0A
<<
OK\x0D\x0A
>>
do productchange "inspection2"
\x0D\x0A
<<
OK\x0D\x0A
5.4.8 History Command Group
Command
Group
Item
Description
Get
History
Passed
This value indicates the number of passed inspections for the active
inspection. This value is cleared (reset) whenever history is cleared.
This value is cleared (reset) when the device starts up or is rebooted.
Get
History
Failed
This value indicates the number of failed inspections for the active
inspection. This value is cleared (reset) whenever history is cleared.
This value is cleared (reset) when the device starts up or is rebooted.
Get
History
MissedTriggers
This value indicates the number of missed triggers for the active
inspection. This value is cleared (reset) whenever history is cleared.
This value is cleared (reset) when the device starts up or is rebooted.
Get
History
StartFrameNumber
This value indicates the starting frame number for the active inspection.
This value is cleared (reset) whenever history is cleared. This value is
cleared (reset) when the device starts up or is rebooted.
Get
History
EndFrameNumber
This value indicates the latest frame number for the active inspection.
This value is cleared (reset) whenever history is cleared. This value is
cleared (reset) when the device starts up or is rebooted.
Get
History
TotalFrames
This value indicates the total number inspections (frames) for the active
inspection. This value is cleared (reset) whenever history is cleared.
This value is cleared (reset) when the device starts up or is rebooted.
Get
History
MinInspectionTime
This value indicates the minimum (fastest) inspection time for the
active inspection. This value is cleared (reset) whenever history is
cleared. This value is cleared (reset) when the device starts up or is
rebooted.
Get
History
MaxInspectionTime
This value indicates the maximum (slowest) inspection time for the
active inspection. This value is cleared (reset) whenever history is
cleared. This value is cleared (reset) when the device starts up or is
rebooted.
Get
History
MinBarcodeCount
This value indicates the minimum number of barcodes read for the
active inspection This value is cleared (reset) whenever history is
cleared. This value is cleared (reset) when the device starts up or is
rebooted.
Get
History
MaxBarcodeCount
This value indicates the maximum number of barcodes read for the
active inspection This value is cleared (reset) whenever history is
cleared. This value is cleared (reset) when the device starts up or is
rebooted.
Do
History
Clear
This command clears all history fields for the active inspection. History
values include pass count, fail count, execution times and sensor
specific history values. This command can be performed using the
sensor's touchscreen.
iVu Plus BCR Communications
24