![Banner iVu Plus BCR Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/banner/ivu-plus-bcr/ivu-plus-bcr_instruction-manual_3761426026.webp)
Command
Group
Item
Description
Set
BCR_INPUT
CompareMask
The Barcode inspection compare string mask in binary format; that is,
masked characters are indicated by a "1" and unmasked characters are
"0." Note that the mask character string must match the length of the
compare string. This value can be modified using the sensor's
touchscreen. This remotely modified value is not persisted to the
sensors permanent memory. The 'Save' operation is required to persist
this value.
5.4.11 BCR_RESULT Command Group
Command
Group
Item
Description
Get
BCR_RESULT
Count
The total number of barcodes found. The most recent inspection value
is used. Access to this value requires a valid trigger.
Get
BCR_RESULT
Data
The decoded barcode data strings. Each string starts and ends with the
double quote character. Multiple values are seperated by the field
delimiter The most recent inspection value is used. Access to this value
requires a valid trigger.
Get
BCR_RESULT
Type
The decoded barcode symbol type(s). Multiple values are seperated by
the field delimiter The most recent inspection value is used. Access to
this value requires a valid trigger.
5.4.12 BCR_HISTORY Command Group
Command
Group
Item
Description
Get
BCR_HISTORY
MinCount
This value indicates the minimum number of barcodes read for the
active inspection This value is cleared (reset) whenever history is
cleared. This value is cleared (reset) when the device starts up or is
rebooted.
Get
BCR_HISTORY
MaxCount
This value indicates the maximum number of barcodes read for the
active inspection This value is cleared (reset) whenever history is
cleared. This value is cleared (reset) when the device starts up or is
rebooted.
5.5 Command Channel Command Status Register
The command status is a verification of the command type.
Command Status
Value (16-bit integer)
Unknown
0
Read
1
Write
2
Execute
3
5.6 Command Channel Error Codes
Table 3: Plus BCR Command Channel Error Codes
Numeric ID
Text ID
Description
00000
SUCCESS
Command processed successfully
10000
EMPTY_FRAME_RECEIVED
Indicates that the request was empty. The command channel
requires a command, any arguments, and an end-of-frame
delimiter.
iVu Plus BCR Communications
26