![Banner iVu Plus BCR Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/banner/ivu-plus-bcr/ivu-plus-bcr_instruction-manual_3761426010.webp)
b. Configure the field and end-of-frame delimiters. Go to Main Menu > System > Communications >
Command Channel > Delimiters.
Valid end-of-frame delimiters are: <comma>, <colon>, <semicolon>, <CR>, <CR><LF>, <LF><CR>, or
<ETX>.
c. Verify that the iVu receives and transmits data correctly.
3. To enable Data Export over Ethernet:
a. Go to Main Menu > System > Communications > Data Export > Connection and select Serial I/O
from the drop-down.
b. Go to Main Menu > System > Communications > Data Export > Data To Export and select the
inspection data to export.
iVu Plus BCR Communications
10