5. Enter the starting time, date, and starting value for the local register.
6. Enter the ending time, date, and ending value for the local register.
5.3 Create Holiday Schedules
Use the Create Holidays tab to create exception conditions that alter the standard scheduled register changes.
To create a holiday:
1. Click on the Add New Rule link.
2. Name your new holiday by clicking on the name link and entering a name.
3. Select the start date and time for the new holiday.
4. Select the stop date and time for the new holiday.
5.3 Power Cycling During Schedules
If power is cycled to the DXM Controller in the middle of a schedule, the DXM Controller will look at all events scheduled
that day and process the last event before the current time.
5.4 LCD and Menu System
Banner Eng
.
08:25:45
→
Registers
→
Push
S
→
08:25:15
→
ISM Radio
→
System
↑
↓
ENTER
BACK
→
System Info
The LCD has four user-defined LED indicators, four control buttons, and an
LCD display. The four buttons control the menu system on the LCD menu.
The top-level menu always displays the time in a 24-hour format.
•
The up and down arrows scroll through display items.
•
The enter button selects the highlighted items on the display
•
The back button returns to a previous menu option.
Main Menu
Sub Menu
Description
Registers
08:25:45
Banner Eng.
12345 Name of Reg1
12345 Name of Reg2
12345 Name of Reg3
12345 Name of Reg4
12345 Name of Reg5
12345 Name of Reg6
↑
↓
ENTER
BACK
The Registers menu displays the user-defined registers and associated
values. The user-defined registers are set up using the DXM Configuration
Tool.
Push
Banner Eng.
08:25:45
→
Trigger Push
Status: ??
Time: ??
↑
↓
ENTER
BACK
The Push menu displays information about the last data sent to the Web
server.
•
The Trigger Push submenu forces an immediate push to the web
server.
•
The status and time fields indicate success or failure of the last
attempted push and time of the last attempted push.