Technical data
Panel PC 2100 user's manual V1.17
55
2.2.4.9 LED status indicators
LED status indicators are located on the bottom of the PPC2100 between the ETH2 interface and the power button.
LED "Power"
LED "CFast"
LED "Link"
LED "Run"
The following intervals are used for the LED status indicators:
Block size: 250 ms
Repeat interval: 500 ms, 2 boxes thus represent one interval
LED
Color
Status
Explanation
LED status indicators
Green
On
Power supply OK
Red
On
The system is in standby mode (S5: soft-off mode or S4: hiber-
nation/suspend-to-disk mode).
Faulty or incomplete BIOS, MTCX or I/O FPGA update, power
supply OK
Power
Red/Green Blinking
Faulty or incomplete BIOS, MTCX or I/O FPGA update, stand-
by mode (S5: soft-off mode or S4: hibernation/suspend-to-disk
mode)
CFast
Yellow
On
Indicates CFast access.
On
Indicates an active SDL connection on the male panel connec-
tor.
An active SDL connection was interrupted by a loss of power
to the panel.
Link
Yellow
Blinking
Information:
Check the power supply / power connector of the
connected panel.
Green
Blinking
Automation Runtime is starting up.
This is controlled by Automation Runtime (ARemb and ARwin).
Green
On
Application running
This is controlled by Automation Runtime (ARemb and ARwin).
Red
On
Application in service mode
This is controlled by Automation Runtime (ARemb and ARwin).
Run
Orange
Blinking
A license violation exists.
This is controlled by Automation Runtime (ARemb and ARwin).
Table 45: LED status indicators - Data