Technical data
Panel PC 2100 user's manual V1.17
201
2.3.5.8 5ACCIF01.FSS0-000
2.3.5.8.1 General information
Interface option 5ACCIF01.FSS0-000 is equipped with 2 RS422/485 interfaces.
•
2x RS422/485 interfaces
•
Compatible with APC2100/PPC2100 and APC2200/PPC2200
2.3.5.8.2 Order data
Model number
Short description
Figure
Interface options
5ACCIF01.FSS0-000
Interface card - 2x RS422/485 interface - For APC2100/
PPC2100/APC2200/PPC2200 - Only available with a new de-
vice
Optional accessories
Terminal blocks
0TB1210.3100
Connector 300 VDC - 10-pin female - Cage clamp terminal block
- Protected against vibration by the screw flange
Table 202: 5ACCIF01.FSS0-000 - Order data
2.3.5.8.3 Technical data
Information:
The following specifications, properties and limit values apply only to this accessory and may deviate
from those that apply to the complete system. For the complete system in which this accessory is
installed, for example, the data specified for that complete system applies.
Model number
5ACCIF01.FSS0-000
General information
LED status indicators
L2, L3
B&R ID code
0xED7B
Certifications
CE
Yes
UL
cULus E115267
Industrial control equipment
HazLoc
cULus HazLoc E180196
Industrial control equipment
for hazardous locations
Class I, Division 2, Groups ABCD, T4
1)
Interfaces
COM
Quantity
2
Type
RS422/RS485, electrically isolated
Design
10-pin, male
UART
16550-compatible, 16-byte FIFO
Max. baud rate
115 kbit/s
Terminating resistor
Type
Can be enabled or disabled using a slide switch
Electrical characteristics
Power consumption
1 W
Operating conditions
Pollution degree per EN 61131-2
Pollution degree 2
Environmental conditions
Temperature
Operation
-20 to 55°C
Storage
-20 to 60°C
Transport
-20 to 60°C
Relative humidity
Operation
5 to 90%, non-condensing
Storage
5 to 95%, non-condensing
Transport
5 to 95%, non-condensing
Mechanical characteristics
Weight
25 g
Table 203: 5ACCIF01.FSS0-000 - Technical data
1)
Yes, although applies only if all components installed in the complete system have this certification and the complete system bears the corresponding mark.