Standards and certifications
306
Panel PC 2100 user's manual V1.17
Model number
Description
DNV GL
beginning
with rev.
5CFAST.4096-00
CFast card, 4 GB SLC
D0
5CFAST.8192-00
CFast card, 8 GB SLC
D0
5CFAST.016G-00
CFast card, 16 GB SLC
D0
5CFAST.032G-00
CFast card, 32 GB SLC
D0
5CFAST.032G-10
CFast card, 32 GB MLC
D0
5CFAST.064G-10
CFast card, 64 GB MLC
D0
5CFAST.128G-10
CFast card, 128 GB MLC
D0
5CFAST.256G-10
CFast card, 256 GB MLC
C0
5ACCIF01.FPCC-000 Interface card - 2x CAN interfaces - 1x X2X Link interface - 1x POWERLINK interface - 512 kB nvSRAM - For APC2100/
PPC2100
C0
5ACCIF01.FPLS-000 Interface card - 1x RS232 interface - 1x POWERLINK interface - 32 kB FRAM - For APC2100/PPC2100 - Only available
with a new device
D0
5ACCIF01.FPSC-000 Interface card - 1x RS232 interface - 1x CAN interface - 1x POWERLINK interface - 32 kB FRAM - For APC2100/PPC2100
- Only available with a new device
D0
0TB103.9
Connector 24 VDC - 3-pin female - Screw clamp terminal block 3.31 mm²
D0
0TB103.91
Connector 24 VDC - 3-pin female - Cage clamp terminal block 3.31 mm²
D0
0TB1210.3100
Connector 300 VDC - 10-pin female - Cage clamp terminal block - Protected against vibration by the screw flange
D0
DNV GL certificates with specifications for permitted environmental conditions are available on the B&R website
at
Downloads - Certificates - Maritime - DNV GL
.
Certificates for compass safe distance are available at
Downloads - Certificates - Maritime - Compass safe distance
.
5.2.7 UL Haz. Loc. certification
Ind.Cont.Eq.
for Haz.Locs.
Cl. I, Div. 2,
Groups ABCD
E180196 (T4)
Products with this mark are tested by Underwriters Laboratories and listed as "indus-
trial control equipment for use in hazardous locations". This mark is valid for the USA
and Canada and simplifies the certification of your machines and manufacturing sys-
tems in this economic region.
Underwriters Laboratories (UL) per standard ANSI/ISA 12.12.01
Canadian (CSA) standard per C22.2 No. 213-16
UL HazLoc certificates are available on the B&R website under
.
5.2.7.1 General safety guidelines
PPC2100 systems with AP923 or AP1000 panels that are certified for use in potentially explosive environments
and carry the marking above are suitable for use in Class 1, Division 2, Groups A, B, C and D or in nonexplosive
environments and correspond to the following standards: UL 508 - 17th Edition, ANSI/ISA 12.12.01:2013, CSA
C22.2 No. 213-M1987, and CSA C22.2 No. 157-92 (R2012).
5.2.7.2 Mounting and installation
Devices with explosion protection are to be used as intended and are only permitted to be operated by knowledge-
able and qualified personnel according to these operating instructions and the other information contained in the
corresponding user's manual. Operation in any other way endangers the safety and functionality of the devices
and the connected systems. The operator is responsible for following all applicable safety and accident prevention
regulations, as well as adhering to standards.
Devices must be installed in a suitable protective housing that can only be opened by using a tool. In order to
guarantee sufficient air circulation, allow the specified amount of space around the device. Use only in environments
with pollution degree 2. The maximum ambient temperature varies depending on the individual components being
"Temperature specifications" on page 32
The certification marking on the device must be checked before each installation or use of the device in potentially
explosive environments. Additional equipment must be suitable for the operating location. Final assembly must be
approved by the relevant local authorities. Wiring must follow national regulations and meet all legal requirements.
Devices must remain voltage-free until installation work is complete. The tightening torque for the power supply
terminals is 0.5 Nm. Cables must be able to handle a surface temperature of 75°C. PPC2100 systems with AP923
or AP1000 panels are only permitted to be operated with 24 VDC.