background image

VT-10100/SKU 11568
VT-10210/SKU 11569

 Flexible Solar Panel

Содержание VT-10100

Страница 1: ...VT 10100 SKU 11568 VT 10210 SKU 11569 Flexible Solar Panel ...

Страница 2: ...on 4 Safety Precautions 5 Installation Procedure and Precautions 5 1 Unpacking and Precautions 5 2 Pre installation Requirements 5 3 Installation Precautions 6 Commissioning and Troubleshooting 7 Product Specifications 8 FAQ 9 Maintenance 1 1 1 2 2 3 5 6 6 7 8 ...

Страница 3: ...be deemed that you have understood acknowledged and accepted all the terms and contents of this document and the user shall be responsible for their actions and all consequences arising therefrom EcoFlow hereby disclaims any liability for any losses due to the user s failure to use the product according to the User Manual In compliance with laws and regulations the company shall have the final rig...

Страница 4: ...her rechargeable batteries etc Use only the relevant equipment connectors wiring and brackets applicable to the installation of this solar module system Always use modules of the same type in a particular PV system Bypass diodes have been integrated into the junction box for all modules For any single module or combination of more than one module connected in series or parallel the cross sectional...

Страница 5: ...e second module In a parallel connection the positive terminals of one module and the second module are connected so are their negative terminals A series connection is shown in the diagram Note 1 Do not step walk stand or jump on any module as uneven stresses may impact the micro cracks on battery cell and ultimately the module s reliability and user experience 2 Do not use sharp tools on the mod...

Страница 6: ...ortest day of the year To generate the most electricity the module should face directly south if it is in the Northern Hemisphere and face directly north if it is in the Southern Hemisphere For details on the best elevation angle for the installation refer to the standard PV installation guide of your locality or the installation angle requirements of a well known solar installer or system integra...

Страница 7: ...e installation method used care should be taken to leave gaps between the panels and the roof to maintain airflow and ensure good heat dissipation for prolonged service life and power generation output Caution 1 Modules should be securely mounted to withstand all expected loads including wind and snow loads 2 Dow Corning is the recommended structural adhesive brand and 3M is the recommended brand ...

Страница 8: ...ith the module completely covered with opaque material then remove the opaque material and measure the open circuit voltage at its terminals and compare 700 W m2 65 0 W ft2 this indicates a poor electrical connection 100 W Flexible Solar Panel General Testing and Certification Rated Power 100 W 5 W Open Circuit Voltage 20 3 V Short Circuit Current 6 3 A Maximum Operating Voltage 17 1 V Maximum Ope...

Страница 9: ...can only be installed in a tiled configuration which prevents the panel s from being installed at 4 Panel Shading The surface of the solar panel should not be shaded during use Shading caused by shadows foreign objects and glass can all greatly reduce power output Performance Issues caused by Malfunctioning Panels If the panel still isn t generating power or its output remains far below expected n...

Страница 10: ...s and do not caused by human force is not covered under the free warranty Does the bend of the 100 W Panel have a large impact on power Can I use 100 W Solar Panels together in series Yes Please read the description of in series and parallel connections in the User Manual carefully paying particular attention to energy storage controller requirements and limitations on solar panel output so as not...

Отзывы: