![B&R 5MP040.0381-01 Скачать руководство пользователя страница 71](http://html.mh-extra.com/html/bandr/5mp040-0381-01/5mp040-0381-01_user-manual_460436071.webp)
Commissioning
Mobile Panel 40/50 User's manual V1.80
71
3.4.2 Connection example for enable
switch
Connection example with monitoring
device
for
safety
circuits up to category 3 PL d per
EN
ISO
13849-1:2008.
Mobile Panel 40/50
(2 enable switches,
each 3-position and 2-circuit)
Evaluation electronics
Circuit 1
Circuit 2
Control cabinet
Attachment cable
5CAMPH.0xxx-30
Enable switch connector (ST1)
Enable
for the
hazardous
movement
DC/DC
converter
Br
ow
n
Bl
ac
k
W
hi
te
R
ed
+
24
V
D
C
Control cabinet cables
5CAMPC.0020-1x
Industrial connector
and
connection housing
Safety relay
Min. category 3 PL d
per EN ISO13849-1:2008.
1) Contacts K1 and K2 must be positively driven!
Fe
ed
ba
ck
Pu
ls
e1
Pu
ls
e2
Sa
fe
In
pu
t 1
Sa
fe
In
pu
t 2
Figure 46: Connection example for enable
switch