![B&R 5MP040.0381-01 Скачать руководство пользователя страница 57](http://html.mh-extra.com/html/bandr/5mp040-0381-01/5mp040-0381-01_user-manual_460436057.webp)
Technical data
Mobile Panel 40/50 User's manual V1.80
57
2.3.2 Cables
2.3.2.1 Attachment cables
2.3.2.1.1 5CAMPH.0xxx-30
2.3.2.1.1.1 General information
An attachment cable establishes the electrical and mechanical connection between the
control
cabinet and
device
.
It contains lines for the network (
Ethernet
10/100 Mbit/s) as well as for the
control
devices and 24 VDC power
supply
1)
.
Female Ethernet RJ45 con shield
(ST2) (4 wires)
Male circular connector
with push-pull locking
Control devices and supply
(ST1) (11 wires)
Figure 34: 5CAMPH.0xxx-30 - Attachment cables
The surface is protected against water, oil (lubricating and hydraulic oils per
EN
60811 Part 2-1) and cooling
lubricant.
The attachment cable is installed in the attachment shaft on the Mobile Panel
device
side. The
control
cabinet
end of the attachment cable has a circular connector. Attachment cables are available in different lengths. For
information about how to connect the attachment cable,
see "Commissioning" on page 66
.
2.3.2.1.1.2 Order data
Model number
Short description
Figure
Attachment cables
5CAMPH.0018-30
MP40/50 attachment cable with push-pull circular connector, 1.8
m
5CAMPH.0050-30
MP40/50 attachment cable with push-pull circular connector, 5
m
5CAMPH.0100-30
MP40/50 attachment cable with push-pull circular connector, 10
m
5CAMPH.0150-30
MP40/50 attachment cable with push-pull circular connector, 15
m
5CAMPH.0200-30
MP40/50 attachment cable with push-pull circular connector, 20
m
Required accessories
Control
cabinet cables
5CAMPC.0020-10
Mobile Panel
control
cabinet cable - Push-Pull circular connector
-
Ethernet
crossover - 2 m
5CAMPC.0020-11
Mobile Panel
control
cabinet cable - Push-Pull circular connector
-
Ethernet
straight-through - 2 m
Optional accessories
Accessories
4MPCBX.0000-00
Mobile Panel connection box - For cables with push-pull circular
connectors
4MPCBX.0000-C01
SIT MP connection box PP
4MPCBX.0001-00
Mobile Panel small connection box - For cables with push-pull
circular connectors
Table 21: 5CAMPH.0018-30, 5CAMPH.0050-30, 5CAMPH.0100-30, 5CAMPH.0150-30, 5CAMPH.0200-30 - Order data
2.3.2.1.1.3 Technical data
Information:
The following specified characteristic data, features and limit values are only valid for these individual
components and may differ from those of the complete system. The data specified for the complete
system applies to the complete system in which this individual component is used, for example.
1)
EN
60950 requirements must be observed; see section "+24 VDC power supply" of the user's manual.