3.3.2 Installing cables in the attachment shaft
After opening the attachment shaft, the connecting lines
can
be installed as shown in the following section.
3.3.2.1 Tips for opening the attachment shaft
•
Place the Mobile Panel
device
on a clean flat surface with the display facing down in a away that does not
damage the Mobile Panel or its operating elements (e.g.
ESD
mat).
•
Loosen the screws with a size 2 Phillips head screwdriver.
3.3.2.2 Notes regarding changes to the attachment shaft
•
Disconnect the main connector (ST1) by pulling carefully on its wires with your fingers (do not use sharp
object
s to help).
•
When disconnecting the RJ45 connector (ST2), make sure that the locking lever is pushed down.
ST2
ST1
ST1
1
2
Figure 43: Disconnecting ST1 and ST2
•
Make sure that the connector locks into place.
3.3.2.3 Note for closing the attachment shaft
•
The gasket must be clean, undamaged and positioned correctly in the attachment shaft cover.
•
Pinched cables are not permitted.
•
The attachment shaft cover must be refastened with all 6 screws (torque: 0.4 to 0.5 Nm). Only then
can
the corresponding degree of protection be ensured again.
3.3.3 Cable outlet
Cable outlet - Right
(cable duct view)
Cable outlet - Left
(cable duct view)
Ethernet cable
Figure 44: Cable outlet