![B&R 5AP92D.1505-I00 Скачать руководство пользователя страница 43](http://html1.mh-extra.com/html/bandr/5ap92d-1505-i00/5ap92d-1505-i00_user-manual_460482043.webp)
Technical data
Automation Panel 9xD - Hygienic design User's manual V 1.80
43
4.1.4.3.3 Grounding
Caution!
The functional ground (power supply pin 2 and ground connec-
tion) must be connected to the central grounding point (e.g. con-
trol cabinet or system) via the shortest possible path with the low-
est possible resistance and with the largest possible wire cross
section. This type of grounding is mandatory for proper function-
ality.
For example, a copper strip must be attached to the ground connection at a central grounding point of the control
cabinet or system in which the device is installed. The wire cross section should be as large as possible (at least
2.5 mm²).
4.1.4.3.4 SDL4 In interface
Information:
For additional information, see section
The SDL4 In interface is a female RJ45 connector and operated with SDL4 transmission technology.
Description
Figure
The following shows an overview of the video signals possible on the panel input. For
details, see the technical data for the link module or panel used.
Variant
RJ45 connector, female
Link module
Video signals
SDL4
-
Information:
Cable lengths and resolutions for SDL4 transfer:
The maximum cable length for SDL4 transfer with a B&R SDL3/SDL4 cable is 100 meters (regardless
of the resolution of the panel).
SDL4 IN LEDs
LED
Color
Status
Explanation
On
Indicates an active SDL4 connection.
Link
Yellow
Off
No active SDL4 connection.
On
The SDL4 connection is established and OK.
Off
No active SDL4 connection.
Status
Yellow
Blinking
Indicates the SDL4 connection is OK, but a
firmware image is corrupt.
Information:
Hot plugging display devices on the SDL4 In interface for service purposes is supported by the hard-
ware and graphics drivers of approved operating systems. The female RJ45 connector is specified for
500 mating cycles.
Information:
If a display device with touch screen is connected to the SDL4 In interface and then disconnected again
during operation (hot plugging), it may be necessary to recalibrate the touch screen.