Technical data
36
Automation Panel 1000 user's manual V2.00
4.1.4.1.5 Temperature monitoring
A sensor in the display monitors the temperature of the AP1000 panel. For the position of the temperature sensor,
see
. The specified values in
represent the defined maxi-
mum temperature for this measurement point. If the temperature is exceeded, no alarm is triggered.
Temperatures
1)
can be read out in different ways in approved operating systems:
•
BIOS
•
B&R Control Center
2)
•
B&R ADI Development Kit
2)
•
B&R ADI .NET SDK
2)
•
B&R HMI Service Center
2)
•
B&R HMI Diagnose
2)
•
B&R PVI ADI line
2)
•
B&R ADI SNMP Agent
2)
•
Automation Runtime library
2)
For applications that do not run in approved operating systems, temperatures can be evaluated using the B&R
MTCX Development Kit. The B&R MTCX Development Kit also contains executable EFI sample programs.
4.1.4.1.6 Temperature sensor positions
A
Figure 7: Automation Panel 1000 - Temperature sensor position
ADI sensors
Position Measuring point
for
Measurement
Max. specified
Panel
A
Display
Temperature of the display
(sensor integrated in the panel).
5AP1120.0573-000: 80°C
5AP1151.0573-000: 80°C
5AP1120.0702-000: 85°C
5AP1130.0702-000: 85°C
5AP1120.101E-000: 80°C
5AP1130.101E-000: 80°C
5AP1120.1043-000: 90°C
5AP1180.1043-000: 90°C
5AP1181.1043-000: 90°C
5AP1182.1043-000: 90°C
5AP1120.1214-000: 80°C
5AP1120.121E-000: 80°C
5AP1130.121E-000: 80°C
5AP1120.1505-000: 90°C
5AP1180.1505-000: 90°C
5AP1181.1505-000: 90°C
5AP1120.156B-000: 80°C
5AP1130.156C-000: 80°C
5AP1130.185C-000: 80°C
5AP1120.1906-000: 80°C
1)
The measured temperature is a guide value for the immediate ambient temperature, but it may have been influenced by neighboring components.
2)
Drivers for approved operating systems can be downloaded at no cost from the Downloads section of the B&R website (
).