Appendix A
200
Automation Panel 1000 user's manual V2.00
A.5.2.5 15" devices
The cutout tolerance for the PP100/200, PP300/400, PP500, AP900, PPC700 and PPC800 is ±0.5 mm.
The cutout tolerance for the AP1000 is +0 mm / -0.5 mm.
435 x 330
8.5 PP500, AP1000
9 PP100/200/300/400, AP900, PPC700, PPC800
9 PP100/200/300/400, AP900, PPC700, PPC800
8.5 PP500, AP1000
10
10
PP100/200/300/400
AP900/PPC700
PP100/200/300/400
AP900
PP500
PP500
0.
5
0.
5
PPC800
AP1000
AP1000
Cutout for PP100/200/300/400/AP900/PPC700/PPC800 device
Cutout for PP500/AP1000 device
Outer contour of device
415 x 312
415 x 313
Figure 110: Installation compatibility - 15" devices - Landscape1
15" Automation Panel 1000 and Power Panel 500 devices are not 100% compatible with Power Panel 100/200,
Power Panel 300/400, Automation Panel 900, Panel PC 700 and Panel PC 800 devices in Landscape1 format.
Automation Panel 1000 and Power Panel 500 devices need a cutout that is 0.5 mm larger (top and bottom edge).
The larger cutout can be used conditionally for all devices:
•
During installation, it is important to ensure that the PP100/200, PP300/400, AP900, PPC700 and PPC800
devices are positioned and installed as centrally as possible in the cutout. If this is not the case, the retaining
clips can no longer grip and impermeability is no longer ensured by the circumferential cord gasket (IP65).
435 x 430
8.5 PP500/AP1000
9 PP100/200/300/400/AP900/PPC700
10
9 PP100/200/300/400/AP900/PPC700
8.5 PP500/AP1000
10
Outer contour of device
Cutout for PP100/200/300/400/AP900/PPC700 device
415 x 412
PP100/200/300/400
AP900
Cutout for PP500 and AP1000 device
415 x 413
PP500
0.
5
0.
5
AP1000
Figure 111: Installation compatibility - 15" devices - Portrait1
15" Automation Panel 1000 and Power Panel 500 devices are not 100% compatible with Power Panel 100/200,
Power Panel 300/400, Automation Panel 900 and Panel PC 700 devices in Portrait1 format. Automation Panel
1000 and Power Panel 500 devices need a cutout that is 0.5 mm larger (top and bottom edge).
The larger cutout can be used conditionally for all devices:
•
During installation, it is important to ensure that the PP100/200, PP300/400, AP900 and PPC700 devices
are positioned and installed as centrally as possible in the cutout. If this is not the case, the retaining clips
can no longer grip and impermeability is no longer ensured by the circumferential cord gasket (IP65).
A.5.2.6 17" devices
The cutout tolerance for the PP100/200, PP300/400, PP500, AP900, PPC700 and PPC800 is ±0.5 mm.
The cutout tolerance for the AP1000 is +0 mm / -0.5 mm.