Accessories
162
Automation Panel 1000 user's manual V2.00
9.4.5.1.6 Cable pinout
If you wish to assemble a suitable cable yourself, the cable must be wired according to this pinout.
Information:
Functionality is only guaranteed for the cables available from B&R.
DVI (24+1), male
Cable shield
Cable shield
DVI (24+1), male
Extender unit
Figure 89: 5CASDL.0xx0-13 - Pinout
Pin
Pinout
Pin
Pinout
1
TMDS data 2 negative
13
XUSB0 positive
2
TMDS data 2 positive
14
+5 V
3
Shielding TMDS data 2 and SDL
15
GND
4
SDL negative
16
Hot plug detection
5
SDL positive
17
TMDS data 0 negative
6
DDC data
18
TMDS data 0 positive
7
DDC clock
19
Shielding TMDS data 0 and XUSB1
8
Not connected
20
XUSB1 negative
9
TMDS data 1 negative
21
XUSB1 positive
10
TMDS data 1 positive
22
TMDS data shield
11
TMDS data 1 and XUSB0 shield
23
TMDS clock positive
12
XUSB0 negative
24
TMDS clock negative
9.4.5.1.7 Cable connection
The SDL flex cable with extender must be connected in the correct direction between the B&R industrial PC and
Automation Panel. For this purpose, the signal direction is indicated on the extender unit.
B&R industrial PC
Figure 90: Example for the signal direction of the SDL flex cable with extender