![B&R Industrial Automation GmbH Power Panel 65 Скачать руководство пользователя страница 65](http://html1.mh-extra.com/html/bandr-industrial-automation-gmbh/power-panel-65/power-panel-65_user-manual_3075569065.webp)
Power Panel 65 • 4PP065.0571-X74F
Power Panel 65 User's manual V2.21
65
2.9.5.3 Ethernet interface
Interface
Pinout
Terminal
Ethernet
1
RXD
Receive signal
2
RXD\
Receive signal inverted
3
TXD
Transmit signal
4
Termination
Termination
5
Termination
Termination
6
TXD\
Transmit signal inverted
7
Termination
Termination
Ethernet interface
1
Female RJ45 twisted pair connector
(10BaseT/100BaseT)
8
Termination
Termination
2.9.5.4 Power supply
The pinout is listed in the following table and printed on the back of the Power Panel. The Power Panel has reverse
polarity protection that prevents the supply voltage from being connected incorrectly and damaging the device.
Overload protection must be provided by an external fuse (5 A, fast-acting).
Power supply
Pinout
Terminal
Assignment
24 VDC
Functional ground
GND
Required accessories
0TB103.9
Connector, 24 VDC, 3-pin female, 3.31 mm² screw clamps, protected against vibration
by the screw flange
3-pin male multipoint connector
0TB103.91
Connector, 24 VDC, 3-pin female, 3.31 mm² cage clamp terminal block, protected against
vibration by the screw flange
Important!
The functional ground must be connected to ground (e.g. control cabinet) using the shortest possible
path. Using the largest possible conductor cross section on the supply connector is recommended.
2.9.6 Key assignments
Key
Bit
Key
Bit
T1
31
T6
23
T2
30
T7
22
T3
29
T8
21
T4
28
T9
20
T5
24
T10
16