The IR80 is a device that accepts an infrared signal from a B&K keypad or an external control receiver and sends 
the received signal out eight 3.5mm mono outputs simultaneously. This device may also be slaved to another 
IR80, which will provide another eight infrared outputs. The IR80 is typically used to provide multiple infrared 
outputs to control preamplifiers, receivers and source pieces within a single installation.   
 

1. Dual Box and Decora Chassis Configuration 

- The IR80 is shipped default as a floor box design (F) for use 

on a shelf, mounting behind a rack or even next to the source. The IR80 may be configured for use in a decora 
wall plate by removing the screws of the chassis and extracting the decora module assembly.

 

2. Input— 

RJ45 CAT-5 input from a CK 1.1 keypad, CK 1.2 keypad or other IR80 module. The conversion 

module uses this input as the source of IR to be sent to the 8 IR Outputs. Maximum length of CAT-5 run should 
be no longer than 500 feet total when powering the IR80 and/or keypad from the CT Receiver or 1,000 feet total 
when powering the IR80 and/or keypad with an external power source.  

3. Pass-Thru—

RJ45 CAT-5 pass through that will send the Input signal (see 2.) to another IR80 distribution 

module, CK 1.2 keypad or CK 1.1 keypad.  

4. Phoenix Input—

Three-position phoenix adaptor for an +12VDC, DATA IN  and ground. When external 

power is needed the ground and +12VDC would be connected to power the IR80.  

5. Eight Flasher Outputs—

Eight flasher outputs are available for sending IR information to source pieces, 

preamplifiers, receivers, etc. All eight flashers would send infrared information simultaneously from the RJ45 
CAT-5 input or the IN on the 3-position phoenix adapter.  

Input 

RJ45 CAT-5 Input from a CK 1.1 keypad, CK 1.2 keypad or other IR80 module. The conver-
sion module uses this input as the source of IR to be sent to the eight 3.5mm IR Outputs. 
Maximum length of CAT-5 run should be no longer than 1,000 feet. When using with another 
IR80 module, CK 1.2 or CK 1.1 keypad the total length of run for all devices can be no longer 
than 1,000 feet. 

Pass-Thru 

RJ45 CAT-5 pass through that will send the Input signal (see above) to another IR80 distribu-
tion module, CK 1.2 keypad or CK 1.1 keypad.  

 Phoenix Input 

Three-position phoenix adaptor for an +12VDC, IN  and 
ground. When external power is needed the ground and 
+12VDC would be connected to power the IR80..  

Front Panel Decora and Box Summary 

Eight Flasher Outputs 

Eight flasher outputs are available for sending IR information to source pieces, preamplifiers, 
receivers, etc. All eight flashers would send infrared information simultaneously from the 
RJ45 CAT-5 input or the IN on the 3-position phoenix adapter.  

Rear Panel Decora and Box Configuration Summary 

CAT5 Audio/Video Drive Pinout 

CAT-5 RJ45 pinouts use the 

T568B

 

standard. See the figure at left. Pins 1 
and 3 send power for up to 500 feet. 
Use of other CAT-5 connection stan-
dards may result in increased signal 
degradation.  

The IR 80 has a maximum length of CAT-5 that should be no longer than 500 feet total when powering the 
IR80 and/or keypad from the CT Receiver or 1,000 feet total when powering the IR80 and/or keypad with 
an external power supply.   

CAT-5 T568B Standard 

The IR80 module accepts an infrared signal from a B&K Keypad and sends a received signal out to eight 3.5mm 
mono outputs simultaneously (note: identical sources with the same IR identification code can not be controlled 
independently). Shown below is an IR80 connected to the Zone Control I/O on a CT Receiver. Then the  CK 1.2 
keypad is connected to the pass-thru input on the IR80 module. This allows for keypad to control the local 
sources through the IR80 module, while still allowing for a pass through to the CT Receiver.   

Connection to a CK 1.2 keypad and CT Receiver 

1. 

CK 1.2 Keypad 

IR80 Module 

CT Zone Control I/O 

Local Source #1 

Local Source #2 

Local Source #3 

The IR80 module is a flexible IR distribution system that can be used in many situations. Shown below is an 
example of the IR80 module used to provide multiple IR outputs to control preamplifiers, receivers and source 
pieces within an installation.   

Connection as a standalone IR distribution module 

IR80 Module 

IR Receiver 

To External Power 

2. 

3. 

4. 

5. 

Отзывы: