2.
After at least several liters (a few gallons) have been used, the
tank should be fully refilled, and the
Set to full
option selected.
3.
Select the
Calibrate
option.
4.
Set the
actual amount used
based on amount of fuel added
to the tank.
5.
Select
OK
to save settings. The
Fuel K-Value
should now show
a new value.
Ú
Note:
To calibrate multiple engines repeat the steps above,
one engine at a time. Alternatively, run all engines
simultaneously, and divide the
Actual amount used
by the
number of engines. This assumes reasonably even fuel
consumption on all engines.
Ú
Note:
The
Calibrate
option is only available when
Set to
full
is selected, and a Fuel Flow is connected and set up as
a source.
Ú
Note:
A maximum of 8 engines is supported using Fuel
Flow sensors.
Fuel Level
With the use of a Navico Fluid Level device connected to a suitable
tank level sensor, it is possible to measure the amount of fuel
remaining in any equipped tank. The number of tanks must be set
in Vessel Setup dialog, initiated from the Fuel setting options page,
to allow discrete tank assignment of the Fluid Level devices.
Select
Device list
on the Network page, and view the Device
Configuration dialog for each sensor, and set the Tank location,
Fluid type, and Tank size.
46
Software Setup
| Vulcan Series Installation Manual
Содержание Vulcan Series
Страница 1: ...ENGLISH VulcanSeries Installation Manual bandg com...
Страница 2: ......
Страница 8: ...8 Preface Vulcan Series Installation Manual...
Страница 64: ...988 11099 001 0980...