Advanced source selection
This allows the most flexible and precise manual control over which
devices provide data. Some data sources, such as those for fuel
level, or engine RPM, can only be changed from the Advanced
menu. Occasionally Auto Select may not assign the desired source,
which may be corrected using the Advanced Source Selection. An
example of this is where twin installations with NMEA 2000
compliant engines are not programmed with unique instance
numbers. This means that the auto select feature cannot determine
which engine is fitted on the port and which is fitted on the
starboard side.
Ú
Note:
The
Advanced
option is visible in multiple places -
the bottom of the
Sources
list, and under each source
category (for example, Compass). The latter shows a filtered
list that only relates to devices that output data relevant to
the category.
Sonar setup
The
Installation
page allows configuration of the internal sonar.
Depth offset
This is a value that can be entered on the Echo Installation page to
make depth readings relate to any point from the water surface, to
the deepest point of the vessel. Below are some typical ways in
which the offset is used:
A) For Depth below Keel: Set the distance from transducer to the
bottom of the keel - this should be set as a negative value. For
example, -2.0.
B) For Depth Below Transducer: no offset required.
C) For Depth Below Surface (waterline): Set the distance from
transducer to the surface - this should be set as a positive value. For
e0.5.
Software Setup
| Vulcan Series Installation Manual