B&D Doors is a division of B&D Australia Pty Ltd
P: 13 62 63
W: www.bnd.com.au
Commercial Door Opener Set Up
GDO-12V1 Hiro
Mount & Connect the Battery
Openers Mounted
a. Mount battery backup kit
30
onto support chassis by sliding down over the slots.
WARNING:
After Step (b) the opener may become active (even when power is off).
This is a result of a residual charge in the batteries.
b. Connect battery harness
32
plug through opening to control board.
Wall Mounted
a. Connect the battery harness extension
35
plug through the opening in the opener to the control board.
b. To wall mount - use the battery pack as template to mark where to drill holes. Pre-drill holes.
i. For plaster walls - insert (2) two Plast wall plugs
34
into holes, place battery backup kit over holes and affix with (2) two
Taptite “P” M3.5 x 8 screws
33
.
ii. For brick walls - place the battery backup kit over the holes and affix with (2) two Taptite “P” M3.5 x 8 screws
33
.
WARNING:
After Step (b) the opener may become active (even when power is off).
This is a result of a residual charge in the batteries.
c. Connect battery harness
32
to the harness extension
35
.
NOTE:
Batteries may take up to 48 hours to charge fully after initial installation.
Re-setup and Test the Opener
a. Reconnect power and remove the button cover.
b. Press the programmed transmitter button to test the battery backup installation.
c. Whilst door is in motion, disconnect mains power. The door should continue to operate as normal.
NOTE:
Wait for the door to complete its travel.
d. Press the progammed transmitter button to activate the door.
e. Whilst door is in motion, reconnect power and re-install button cover. The door should complete the cycle as normal.