Figure 5.7: SI Series external chemical injection points
Attempting to obtain power from the machine terminals may damage the ma-
chine circuit and/or the chemical injection system. Consult the chemical injec-
tion supply system instructions for operational details.
5.11.2
Chemical Signal Connections
Connection terminals are located in the rear control box for output signals to the chemicals injec-
tion supply pump. Refer to figure 5.8 on page 28.
Terminals SUPPLY 1 through SUPPLY 8 provide signals for external chemical supply pumps. The
signal is a maximum of 1 amp at 24V 50/60Hz.
Do not attempt to increase circuit breaker rating as this will cause damage to the washer-extractor
circuitry and void the warranty.
Any injection system pump, which requires 24-220V AC must be powered by a separate external
power source.
5.12
Optional Loading Chute Installation
Refer to figure 5.9 on page 29.
NOTE: It is highly recommended that the bearing housings for
the chute be welded in place
•
Safely raise Chute above machine until the 4 mounting bolts are aligned and bolts can be
27
Содержание SI Series
Страница 1: ...Washer Extractor SI Series Installation and Operation Manual 9 Sep 2013 Revision 2 20 ...
Страница 6: ...Figure 1 1 SI Product Family 2 ...
Страница 14: ...Chapter 4 General Specifications 10 ...
Страница 15: ...Figure 4 1 SI Series General Specifications 11 ...
Страница 33: ...Figure 5 9 Loading Chute Installation 29 ...
Страница 34: ...Figure 5 10 Loading Chute Up Switch Installation 30 ...
Страница 40: ...Figure 6 2 Chute Maintenance Switch 36 ...
Страница 50: ...Figure 7 2 Hydraulic Pump Detail for models with Loading Chute Option Figure 7 3 Hydraulic Pump Adjustment 46 ...