Never touch internal or external steam pipes, connections, or components. These
surfaces can be extremely hot and will cause severe burns. The steam must be
turned off and the pipe, connections, and components allowed to cool before the
pipe can be touched.
Table 5.7: Steam Service Consumption Data
MODEL
Units
SI-110
STEAM INLET and CONSUMPTION:
Steam inlet size
DN
in
20
3/4
Required steam to heat bath 10F (6C)LOW
kg
lbs
3.15
7
Required steam to heat bath 10F (6C)HIGH
kg
lbs
4.77
10.5
Average Steam consumption per cycle
kg
lbs
72
158
MODEL
Units
SI-135
STEAM INLET and CONSUMPTION:
Steam inlet size
DN
in
20
3/4
Required steam to heat bath 10F (6C)LOW
kg
lbs
3.8
8.4
Required steam to heat bath 10F (6C)HIGH
kg
lbs
5.8
12.76
Average Steam consumption per cycle
kg
lbs
88
194
MODEL
Units
SI-200
STEAM INLET and CONSUMPTION:
Steam inlet size
DN
in
25
1
Required steam to heat bath 10F (6C)LOW
kg
lbs
5
11
Required steam to heat bath 10F (6C)HIGH
kg
lbs
7.7
16.9
Average Steam consumption per cycle
kg
lbs
117
194
MODEL
Units
SI-275
STEAM INLET and CONSUMPTION:
Steam inlet size
DN
in
25
1
Required steam to heat bath 10F (6C)LOW
kg
lbs
5.25
11.5
Required steam to heat bath 10F (6C)HIGH
kg
lbs
7.95
17.5
Average Steam consumption per cycle
kg
lbs
120
260
24
Содержание SI Series
Страница 1: ...Washer Extractor SI Series Installation and Operation Manual 9 Sep 2013 Revision 2 20 ...
Страница 6: ...Figure 1 1 SI Product Family 2 ...
Страница 14: ...Chapter 4 General Specifications 10 ...
Страница 15: ...Figure 4 1 SI Series General Specifications 11 ...
Страница 33: ...Figure 5 9 Loading Chute Installation 29 ...
Страница 34: ...Figure 5 10 Loading Chute Up Switch Installation 30 ...
Страница 40: ...Figure 6 2 Chute Maintenance Switch 36 ...
Страница 50: ...Figure 7 2 Hydraulic Pump Detail for models with Loading Chute Option Figure 7 3 Hydraulic Pump Adjustment 46 ...