5.3
Dimensional Clearances
When installing the washer-extractor, it is important to allow adequate clearance on all sides of the
machine. When multiple machines are installed, it is important to allow for the specified minimum
clearances between machines. Figures 5.1 and 5.1 show recommended minimum clearances for
the various freestanding models.
Note: The dimensions are approximate and subject to normal manufacturing tolerances. If
exact dimensions are required for construction purposes, request certified drawings from the
factory. We reserve the right to make changes at any time without notice.
Figure 5.1: Minimum Service Clearances
Table 5.1: Minimum Service Clearnances
UNITS
UNITS
SI Series
SI Series Tilt
Metric
US
(A) Minimum rear clearance
mm
in
760
30
760
30
(B) Minimum clearance between machine and wall
mm
in
455
18
455
18
(C) Minimum clearance between machines
mm
in
455
18
455
18
(D) Minimum front clearance
mm
in
850
33
1220
48
5.4
Machine Foundation
Thoroughness of details must be stressed with all foundation work to insure a stable unit installa-
tion, eliminating possibilities of excessive vibrations during extraction.
17
Содержание SI Series
Страница 1: ...Washer Extractor SI Series Installation and Operation Manual 9 Sep 2013 Revision 2 20 ...
Страница 6: ...Figure 1 1 SI Product Family 2 ...
Страница 14: ...Chapter 4 General Specifications 10 ...
Страница 15: ...Figure 4 1 SI Series General Specifications 11 ...
Страница 33: ...Figure 5 9 Loading Chute Installation 29 ...
Страница 34: ...Figure 5 10 Loading Chute Up Switch Installation 30 ...
Страница 40: ...Figure 6 2 Chute Maintenance Switch 36 ...
Страница 50: ...Figure 7 2 Hydraulic Pump Detail for models with Loading Chute Option Figure 7 3 Hydraulic Pump Adjustment 46 ...