Web-Based Management
6.8.3 System Event Log
—Event Configuration
Having marked the
Syslog
/
SMTP
checkboxes, the event log/email alert will be sent
to the system log server and the SMTP server respectively. Also, Port event
log/alert (link up, link down, and both) can be sent to the system log server/SMTP
server respectively by setting the trigger condition.
System event selection:
There are 4 event types
—Device Cold Start, Device
Warm Start, Authentication Failure, and X-ring Topology Change. The
checkboxes are not available for marking unless the
Syslog Client Mode
on
the Syslog Configuration tab and the
E-mail Alert
on the SMTP Configuration
tab are enabled first.
Device cold start:
When the device executes cold start action, the
system will issue the event log/email alert to the system log/SMTP server
respectively.
Device warm start:
When the device executes warm start, the system will
issue the event log/email alert to the system log/SMTP server respectively.
Authentication Failure:
When the SNMP authentication fails, the system
will issue the event log/email alert to the system log/SMTP server
respectively.
X-ring topology change:
When the X-ring topology has changed, the
system will issue the event log/email alert to the system log/SMTP server
respectively.
Port event selection:
Before the drop-down menu items are available, the
Syslog Client Mode
selection item on the Syslog Configuration tab and the
E-
mail Alert
selection item on the SMTP Configuration tab must be enabled first.
Those drop-down menu items have 3 selections
—
Link UP
,
Link Down
, and
Link UP & Link Down
. Disable means no event will be sent to the system
log/SMTP server.