5.  To replace Gripper: Make sure Tension Block is all the way forward against the tool head.  Remove drill.  Remove 

tool  adapter  body.    Remove  one  side  of  the  tool  body  or  the  other,  not  both.    Slide  Gripper  out  sideways  and 
replace with a new one.  Re-attach Tool Body side.  

Caution:  

Do not push or move Tension Block while Gripper is 

out of tool. 

 

Tension 

Screw 

M00987 

Move tension 

block all the way 

forward against 

the tool head 

Tool Head 
M00587 

Gripper 

M08887 

Screw, #10-32 

M06187 

Figure 12 

6.  To replace Tension Screw: Move Tension Block all the  way back (away from Tool Head) using drill  in tensioning 

mode  (clock-wise).    Remove  Ultra-Lok

  Tool  from  Drill.    Remove  the  Tool  Adapter  from  the  Ultra-Lok

  Tool.  

Remove  Blade  and  load  bearing  tip  from  Tensioning  Screw  (see  bearing  detail).    Remove  one  side  of  the  Tool 
Body or the other, not both.  Grasp the smooth barrel on Tension Screw and pull all the way forward until Tension 
Block is against the Tool Head.  If Tension Screw is stuck, use a punch and tap the center of the screw from the 
back end of the tool.  Turn Tension Screw out of Tension Block.  Lubricate new Tension Screw with Molybdenum 
Disulfide  lubricant,  or  equivalent.    Install  new  Tension  Screw  in  reverse  order;  making  sure  that  back  end  of 
Tension Screw extends well beyond the back end of the Tension Block.  Push the assembly all the way back and 
extend the round portion of the Tension Screw through holes on the tripper bracket and back guide plate.  Reinstall 
Tool Body side.  Reinstall Blade and tighten the Blade Mounting Screws approximately 120 in-lbs.  Reattach Tool 
Adapter to Ultra-Lok

 Tool.  Reattach Tool to Drill and drive Tension Block all the way forward. 

 

Note:  Drills needing repair must be returned to Band-It. 

 

 

Содержание UL4000-D

Страница 1: ...ment P09986 Rev B A Unit of IDEX Corporation Copyright 4799 Dahlia Street www BAND IT IDEX com BAND IT IDEX Inc 2016 Denver CO 80216 0307 USA All Rights Reserved P 1 800 525 0758 F 1 800 624 3925 1 Op...

Страница 2: ...IT IDEX Inc 2016 Denver CO 80216 0307 USA All Rights Reserved P 1 800 525 0758 F 1 800 624 3925 2 Contents Warranty and Safety Guidelines 3 Setup Instructions 4 Tool Settings 6 Parts List 7 Exploded V...

Страница 3: ...d instructions are in this manual and the operator is advised to read it and become familiar with operating the tool IMPORTANT FOR HOSE APPLICATIONS When clamping a hose end remember that a tighter cl...

Страница 4: ...pter M07697 on the Tension Tool UL0001 with 20 30 in lbs b Place the Adapter Collar M08288 over the Tool Body Adapter c Orient the Drill Clutch Pin M07187 horizontally see page 5 Figure 2 d Carefully...

Страница 5: ...00 525 0758 F 1 800 624 3925 5 Drill Clutch M04298 Note Tool Body Adapter and Adapter Collar are hidden for clarity Tension Screw M00987 UL Tool Body NOTE Alignment is critical for proper tool functio...

Страница 6: ...lutch settings will alter tension output Drill Trigger should be depressed fully by the operator to attain correct and consistent tension when installing clamps Tension output may vary from tool to to...

Страница 7: ...4 Screw Socket Head Cap X 23 M06187 6 Screw Socket Head Cap 10 32 X 3 8 24 M02487 2 Screw Spring Plunger 20 25 A33887 1 Spring Compression 180 X 813 Long 26 A53587 2 Spring Compression 300 X 1 00 Long...

Страница 8: ...of IDEX Corporation Copyright 4799 Dahlia Street www BAND IT IDEX com BAND IT IDEX Inc 2016 Denver CO 80216 0307 USA All Rights Reserved P 1 800 525 0758 F 1 800 624 3925 8 Exploded View 18 28 6 19 2...

Страница 9: ...ent under spring load when assembled 10 7 32 Brush lubricant evenly on threads 2 Places 26 31 8 16 32 31 All around inside profile both sides Tension Gripper Assembly Tool Head Assembly See page 6 for...

Страница 10: ...lace of a Free End 4 Position the tie on the object you are clamping Pull the wrapped tie hand tight Slightly bend the tail up to keep the clamp in place 5 Actuate Drill until Tension Block is all the...

Страница 11: ...lamp Inspect buckle on the completed clamp and tap down the buckle shroud FRONT VIEW Completed Free End Clamp Visually inspect lock Buckle Shroud Shear Surface Bad Clamp Lock has slipped back under sh...

Страница 12: ...inally complete clamp by tapping down the buckle shroud as described above Trouble Shooting 1 Lock slips down in buckle Tighten blade mounting screws If lock on clamp is still not adequate reduce tens...

Страница 13: ...tem 1 Lubricating Syringe Reorder C23199 Bearing Detail Figures 9 and 10 3 To gain access to bearing components remove blade Mounting Screws 2 places and slide Blade free Paper clip may be used to pus...

Страница 14: ...om Drill Remove the Tool Adapter from the Ultra Lok Tool Remove Blade and load bearing tip from Tensioning Screw see bearing detail Remove one side of the Tool Body or the other not both Grasp the smo...

Страница 15: ...tool in order to remove blade Figure 13 Remove the 3 4 shear plate from the blade 4 Align the 1 2 Shear Plate M09387 with the Blade M09787 so that the guide is facing up Incorrect placement will not...

Отзывы: