54
User Manual
IT8000 3/8” TIE
-LOK DATA TOOL
IT7000 1/4” TIE
-LOK DATA TOOL
ITC800 CONTROL SYSTEM
Document # P80080 Rev. C.3
© Copyright
BAND-IT-IDEX, Inc. 2024
All rights reserved
All rights reserved
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street
Denver, CO 80216-3070 USA
P: 1-800-525-0758
Table 8
–
Error Code Summary Table:
Number
Description
Details
135
Band Slipping
Detected
This error occurs when large changes in motor velocity are detected, and the number
of detections exceeds the amount of allowable slipping events defined on the HMI.
When this error is triggered, the tool will fault, the LED will blink red, and the
sequence will end.
Possible Cause:
See
“
Pre-set tension is not reached
” troubleshooting section.
144
Tool Line Up
Timeout
This error occurs when the time limit set by the “Line Up Tool Timeout” setting on the
HMI is exceeded before the contact switches are triggered. When this error is
triggered, the tool will fault, the LED will blink red, and the sequence will end.
Possible Cause:
Buckle/proximity sensors are not functioning correctly.
155
General
Servo Fault
Detected
This error occurs when the servo and/or the drive are in a faulted state. When this
error is triggered, the tool will fault, the LED will blink red, and the sequence will end.
Possible Cause:
Obstruction in drivetrain.
212
Parameters
Not Passed
–
Punch
Duration Out
of Range
This error will occur after a completed cycle if the measured "Punch Duration" is
outside of the allowed range set on the HMI.
Possible Cause:
Obstruction in punch assembly, damaged punch cylinder.
213
Parameters
Not Passed
–
Torque Out
of Tolerance
This error will occur after a completed cycle if the measured motor torque is outside
of the allowed range set on the HMI for the set monitoring period. The torque is
monitored from the point where it reaches the torque tolerance band and through
tightening until after the punch operation.
Possible Cause:
Tolerance settings too tight, worn motor/gearbox.
224
Parameters
Not Passed
–
Contact
Switch Lost
Contact
This error will occur after a completed cycle if the contact switches lose contact
during the monitoring period. The contact switches are monitored from the time they
are first lined up to just after the punch.
Possible Cause:
Operator movement during installation process
311
Supply
Pressure Out
of Range
This message will display when the trigger is pressed, and the supply pressure is
outside of the range defined on the HMI.
Possible Cause:
Regulator set incorrectly
312
Punch
Pressure Out
of Range
This message will display on the HMI while waiting for the punch pressure
measurement to reach the set pressure range. If the punch pressure is achieved, the
message will clear, and the tool will continue the sequence normally.
Possible Cause:
Regulator set incorrectly
313
Torque Out
of Tolerance
Before Cut
This message will display if the tool has completed the punch operation and motor
torque has left the set torque tolerance before the tool completes the band cutting
operation. The message will persist until the tool adjusts tension back to within
tolerance, at which point it will automatically clear.
Possible Cause:
See
“
Pre-set tension is not reached
” troubleshooting section.