HEAD REPLACEMENT
Remove the Head Cover (1). Remove the E-Clips 2x (2) on the motor side only. Pull the pins 2x (3) out of the
head. Swing the Linkages (4) down to access the head bolts. Remove the bolts (7/64
” hex
key) 4x (5). Disconnect
the sensor cable and remove the head (6).
Apply a film of grease on the pins and knife and reassemble. Ensure that the upper pin goes through the trigger
assembly linkage (7) (Fig. 81). Apply Blue Loctite to screws. Only pull-on gray cable jacket when connecting head
sensor.
The pneumatics cover or side cover may need to be removed to reconnect the head sensors or to insert the
pins.
Replacement Head Kit Part Number:
Tool
IT8000
IT7000
Part Number
H80945 or H80940 (no sensors)
H70945 or H70940 (no sensors)
Important:
Prior to any maintenance or disassembly,
be sure to disconnect all power sources to
the tool and discharge pressurized air from
the air system.
1
2
3
4
5
6
7
Figure 80