Observed Problem
Possible Cause
Solution
No power to tool or sub-components
Unplugged power cord /
connectors.
Check power cord. Check all connections
between components. Be sure to match
connector styles, number of pins on
individual connections and observe keyed
orientation of the connectors. All
threaded sleeves on connectors must be
fully assembled and secured.
Power entry plug switch
or door latch turned Off
Check switch status.
Internal Circuit
Breaker(s) tripped to
Off position.
Check to make sure all Circuit Breakers are
in the On position (located inside the
Electrical Control box).
Tool does not activate when the trigger is
pulled.
E-stop is pressed down Check switch status
Manual mode is
activated
Tool will not install a clamp in manual
mode, turn off to go to normal operation
External trigger is on.
Turn off external trigger.
Can not reset servo fault error: F-12 Fault on
servo drive
Grounding braid of
motor cable
damaged/disconnected
Replace H80122 motor cable