TOOL SETUP
OPERATING REQUIREMENTS
Table 2
Clamp Type
BAND-
IT 3/8” Tie
-Lok® Tie Series
BAND-IT 1/4
”
Tie-Lok® Tie Series
Operation Air Requirements
80 PSI (552 kPa) Clean dry compressed air
Air Flow Rate: 0.25 CFM (7.1 L/min.)
Do not exceed 100psi (690kPa) into panel.
Input supply not to exceed max listed on
regulator assembly.
Power requirements
110Volts/60Hz or 240Volts/50Hz Grounded AC
8 A Max
5kA SCCR
Power Cord
North America: 120V, 15A, 14AWG
Cord Receptacle: IEC 60320 C13
Human-Machine Interface (HMI)
Programmable Color Touchscreen
Emergency Stop
Application of emergency stop button will stop
electric motor and open all valves, removing air
pressure from pneumatic cylinders.
Power Output
Motor: 240V, 3.1A MAX, 8kHz
HMI: 24V, 350mA
Data Cable: 24V, 2A
Airborne Noise Emissions
A-Weighted Pressure level: 70 dBA
Peak C-Weighted Pressure Level: 71 dBA
Vibration Data
–
Handheld Unit
Continuous: 3.2 m/s
2
Peak: 30.2 m/s
2
@ cutoff