Mount the BV-520 valve with an appropriate fixture, using the ¼-
20 Thread UNC DP5 on the air cylinder body or using M6 x 1P 
DP5 TAP on the fluid chamber.

Connect the control air line to the valve controller or other 
pneumatic switch that is used to control operating air to the valve.

Connect the fluid feed hose to the fluid inlet fitting and fluid
reservoir.

The valve fluid chamber with inlet fitting can be rotated to prevent 
possible interference with machine parts. 

To reposition the fluid chamber, first turn the needle stroke control 
out two full turns 

, then rotate the chamber 

to the desired 

position.

5. Setup

5. Setup

Set stroke 

adjustment two full 
turns out.

Rotate fluid 

chamber to 
desired position.

Note:

Do not rotate fluid 

chamber more than one 
complete turn.

Fill the fluid reservoir.

After filling, check to be certain the reservoir cover is secured and 
that all connections are tight.

Set the reservoir pressure. For low viscosity fluids, start with a 
pressure of approximately 0.3 bar (5 psi). For higher viscosity, use 
1.4 to 2.8 bar (20 to 40 psi). Increase or decrease as necessary.

Note:

If solvents or other watery fluids are to be dispensed in very 

small amounts, specify 0 to 1.0 bar (0 to 15 psi) precision 
regulator to control reservoir pressure.

Set the needle stroke. Start at one full turn open.

Set the valve control air pressure to 4.8 bar (70 psi).

Open the valve with an air pulse long enough to fill the valve and 
start fluid flow. Then test the dispensed amount with a nominal 
time setting.

Increase or decrease reservoir pressure, needle stroke and valve
open time to arrive at the desired deposit size.

Содержание BV-520P

Страница 1: ...656 253 Sungsu 1ka Sungdong ku Seoul Korea TEL 02 469 1239 FAX 02 497 1270 E MAIL banseok banseok co kr WEB SITE www banseok co kr BV BV 520P 520P User Manual User Manual...

Страница 2: ...s 1 Specifications Size 114 6mm x 26 9mm 4 510 x 1 060 diameter Weight 300g Fluid inlet thread 1 8 PT Female Fluid outlet M3 5 x 0 6P TAP Air pressure required 4 8 bar 70 psi Maximum input fluid press...

Страница 3: ...mplete air is exhausted back through the valve controller ensuring rapid and positive fluid shutoff The BV 520 can be operated in any position without affecting flow Vibration normally has no effect o...

Страница 4: ...ment two full turns out Rotate fluid chamber to desired position Note Do not rotate fluid chamber more than one complete turn Fill the fluid reservoir After filling check to be certain the reservoir c...

Страница 5: ...656 253 Sungsu 1ka Sungdong ku Seoul Korea TEL 02 469 1239 FAX 02 497 1270 E MAIL banseok banseok co kr WEB SITE www banseok co kr 6 BV 6 BV 520 Exploded View 520 Exploded View...

Страница 6: ...tion tool is not included Figure 1 Figure 1 Do not use sharp instruments to scrape or clean these components Scratches may cause the valve to leak 5 Remove any remaining packings and the packing sprin...

Страница 7: ...n return spring and thrust washers located on each end of the spring 3 Remove the snap ring using snap ring pliers 4 Pull the piston and needle assembly out of the cylinder using small pliers on the s...

Страница 8: ...e indicates the needle packings are worn Replace needle packings Fluid leaks out the drain hole A steady drip can be caused by a worn needle and seat or a particle holding the needle off the seat Remo...

Отзывы: