3. How the Valve Operate

3. How the Valve Operate

The BV-520 valve is a normally 
closed, fail-safe, adjustable opening 
needle valve.

The amount of fluid dispensed is 
determined by length of time the 
valve is open;fluid reservoir 
pressure; needle stroke; and fluid 
viscosity.

The BV-520 requires 4.8 bar (70 
psi) air pressure. This air pressure 
acting on the piston 

retracts the 

piston and needle 

from the 

needle seat 

, permitting fluid flow 

from the output 

. Piston and 

needle stroke and fluid flow are 
controlled by the stroke control 
knob 

.

Once the cycle is complete, air is 
exhausted back through the valve 
controller, ensuring rapid and 
positive fluid shutoff.

The BV-520 can be operated in any 
position without affecting flow. 
Vibration normally has no effect on 
performance. The valve can be 
moved in and out of dispense 
position at high-cycle rates (such as 
a reciprocation device installed on a 
production line) without affecting 
dispensing performance.

4. Stroke Control Reference

4. Stroke Control Reference

The Stroke Control 
Reference feature is used 
to calibrate the stroke 
control setting or document 
the dispensing process.

To calibrate the valve, the 
stroke control knob is first 
closed all the way. The set 
screw is then loosened and 
the stroke reference ring 
turned so that the zero on 
the reference ring is aligned 
with one of the two 
reference marks engraved 
on the valve body. When 
the set screw is tightened, 
the valve is calibrated.

Содержание BV-520P

Страница 1: ...656 253 Sungsu 1ka Sungdong ku Seoul Korea TEL 02 469 1239 FAX 02 497 1270 E MAIL banseok banseok co kr WEB SITE www banseok co kr BV BV 520P 520P User Manual User Manual...

Страница 2: ...s 1 Specifications Size 114 6mm x 26 9mm 4 510 x 1 060 diameter Weight 300g Fluid inlet thread 1 8 PT Female Fluid outlet M3 5 x 0 6P TAP Air pressure required 4 8 bar 70 psi Maximum input fluid press...

Страница 3: ...mplete air is exhausted back through the valve controller ensuring rapid and positive fluid shutoff The BV 520 can be operated in any position without affecting flow Vibration normally has no effect o...

Страница 4: ...ment two full turns out Rotate fluid chamber to desired position Note Do not rotate fluid chamber more than one complete turn Fill the fluid reservoir After filling check to be certain the reservoir c...

Страница 5: ...656 253 Sungsu 1ka Sungdong ku Seoul Korea TEL 02 469 1239 FAX 02 497 1270 E MAIL banseok banseok co kr WEB SITE www banseok co kr 6 BV 6 BV 520 Exploded View 520 Exploded View...

Страница 6: ...tion tool is not included Figure 1 Figure 1 Do not use sharp instruments to scrape or clean these components Scratches may cause the valve to leak 5 Remove any remaining packings and the packing sprin...

Страница 7: ...n return spring and thrust washers located on each end of the spring 3 Remove the snap ring using snap ring pliers 4 Pull the piston and needle assembly out of the cylinder using small pliers on the s...

Страница 8: ...e indicates the needle packings are worn Replace needle packings Fluid leaks out the drain hole A steady drip can be caused by a worn needle and seat or a particle holding the needle off the seat Remo...

Отзывы: