Section 8: Repairs
Bambi MAX Service Manual
– Models HL4000-HL9800 48
11.
Connect the control cable to a 24-28 volt DC power
source, open the valve about a 1/3 of the way and cut
the power. The cable anchor should be close to the
position shown in this picture. Feed the cable through
the cable anchor, pull it snug but do not tighten.
12.
Install a 7/16" spacer plate between the sheave bar
and lift bar. Place a heavy weight on the lift bar to
hold it down.
13.
Turn on the power. The valve will close. Pull the
cable tight and secure with cable anchor screws.
14.
Install a piece of 1/8" x 1" heat shrink over the cable
next to the anchor. Cut off the excess cable as close
to cable anchor as possible.