background image

17 / 18

0006081092_201305

ENGLISH

• 

Press "11" TO DeLeTe.

• 

CUT POWer TO THe UniT fOr 20 

seC.

• 

resTOre POWer

• 

Press "f3" TWiCe.

• 

Press "5", "7", "8" aT THe same 

Time

• 

Press "11"

END OF STROKE UPDATE

Содержание ETAMATIC OEM

Страница 1: ...s et systèmes pour la technologie de la combustion avec contrôle CO YanmateknolojineyönelikCOkontrollüsensorvesistemler датчики и системы для технологии сжигания топлива с устройством контроля CO CO 检测燃烧技术所采用的传感器和系统 ISTRUZIONI ORIGINALI IT ORIGINAL INSTRUCTIONS IT INSTRUCCIONES ORIGINALES IT ISTRUCTIONS ORIGINALES IT ORİJİNAL KULLANIM KILAVUZU IT ОРИГИНАЛЬНЫЕ ИНСТРУКЦИИ ПЕРЕВОД С ИТАЛЬЯНСКОГО ЯЗЫК...

Страница 2: ......

Страница 3: ...clusivamente a personale qualificato Per informazioni dettagliate su altre considerazioni per l uso della centralina e le relative precauzioni consultare il Manuale utente completo disponibile sul sito Baltur Il presente catalogo riveste carattere puramente indicativo La casa pertanto si riserva ogni possibilità di modifica dei dati tecnici e quant altro in esso riportato PARAMETRI INVERTER PREIMP...

Страница 4: ...F1 517 100 campo della correzione per la regolazione definitiva vedi modalità TK 718 200 regolatore interno 500 per regolazione a 3 punti 0 per segnale 4 20 mA 758 Post ventilazione 0 esclusa max 1000 secondi 774 pilota 0 escluso 1 inserito 775 pilota 0 escluso 1 inserito 780 tempo pilota 783 tempo stabilizzazione fiamma 787 maintenence mode 1 per regolare pilota 790 regolatore di carico 0 escluso...

Страница 5: ...l sistema è pronto per la calibrazione premere CALL START CALIBRATION ENTER off set calibration on ambient air ENTER apparirà call Off set ed il sistema è in calibrazione quando apparirà MEAESURE la sonda sarà calibrata EXIT TARATURA DELLA SONDA O2 CON BRUCIATORE IN FUNZIONAMENTO Una volta regolata la combustione portare il bruciatore a circa il 2 di O2 Agire sulla tastiera dell LT2 CALL START CAL...

Страница 6: ...RI ETAMATIC Cercare di avere la stessa differenza di portata tra un punto e l altro P9 P1 8 Regolazione digit potenziometro Servomotore gas min max Servomotore aria min max N PAR DIGIT N PAR DIGIT N PAR DIGIT Durante il funzionamento a gasolio mantenere un buon eccesso d aria al camino O2 5 6 Verificare la fumosità nella minima e massima potenza termica del bruciatore tramite pompa BACHARA per evi...

Страница 7: ...92_201305 ITALIANO PARAMETRI INVERTER PREIMPOSTATI DA BALTUR DATI DI TARGA MOTORE 9905 9906 9907 9908 9909 1003 1 1104 30 1105 50 1201 0 1301 20 verificare che il jumper sia posizionato in I corrente segnale 4 20mA ...

Страница 8: ...092_201305 ITALIANO SHERMATA PRINCIPALE PREMERE 5 7 8 CONTENPORANEAMENTE PREMERE 11 PER CONFERMARE SI ACCEDE AL LIVELLO 1 PREMERE F3 DUE VOLTE PREMERE 11 PER CONFERMARE APPARIRA CANCELLATO IMMETTERE UNA NUOVA CURVA ...

Страница 9: ...IUDERE LA LINEA TERMOSTATICA ED ATTENDERE QUANDO APPARIRÁ PLEASE SET IGNITION POINT PREMERE IL TASTO 16 VERIFICARE IL CARICO DI ACCENSIONE 2 SZP PREMERE 16 I M P O S TA R E I L P U N TO D I ACCENSIONE UTILIZZANDO I TASTI DAL 2 AL 9 PREMERE 11 PER CONFERMARE ...

Страница 10: ...TORE É ACCESO VERIFICARE LA COMBUSTIONE PREMERE 17 CON I TASTI 2 E 3 IMPOSTARE IL CARICO MINIMO PREMERE 16 IMPOSTARE LA POTENZA MINIMA DEL BRUCIATORE VERIFICARE LA COMBUSTIONE UNA VOLTA IMPOSTATO IL PUNTO DI MINIMA CON I TASTI DAL 2 AL 9 PREMERE 11 PER CONFERMARE PREMERE 17 ...

Страница 11: ...1305 ITALIANO CON I TASTI 2 E 3 IMPOSTARE IL CARICO MASSIMO PREMERE 16 UNA VOLTA IMPOSTATO IL PUNTO DI MASSIMA CON I TASTI DAL 2 AL 9 PREMERE 11 PER CONFERMARE CON I TASTI 2 E 3 MODIFICARE IL CARICO PREMERE 16 PREMERE 17 ...

Страница 12: ... 0006081092_201305 ITALIANO REGOLARE IN COMBUSTIONE CON I TASTI DAL 2 AL 9 IL PUNTO PREMERE 11 VERIFICARE LA COMBUSTIONE IN TUTTI I PUNTI DELLA CURVA 2 200 300 400 500 600 700 800 900 990 MEMORIZZARE CON F2 ...

Страница 13: ...NTE PREMERE 11 PER CONFERMARE SBLOCCO LIVELLO 1 PREMERE F3 PREMERE 16 CON I TASTI 2 E 3 PORTARSI SUL VALORE DEL CARICO DA MODIFICARE PREMERE 16 CON I TASTI DAL 2 AL 9 SISTEMARE IL PUNTO CHE SI É SELEZIONATO PREMERE 11 PER CONFERMARE MODIFICARE UNA CURVA ESISTENTE ...

Страница 14: ...8 0006081092_201305 ITALIANO ESEGUIREQUESTAOPERAZIONEPERI PUNTI CHE SI VOGLIONO MODIFICARE AL TERMINE PREMERE F2 PER MEMORIZZARE PREMERE 5 7 8 CONTEMPORANEAMENTE PREMERE 11 PREMERE F2 IMPOSTARE LA CURVA O2 ...

Страница 15: ...O2 TASTI 2 3 PREMERE 16 CON I TASTI 8 E 9 IMPOSTARE IL VALORE DI O2 PREMERE 11 PER CONFERMARE PREMERE 17 IMPOSTARE IL VALORE DEL CARICO CON I TASTI 2 E 3 PREMERE 16 IMPOSTARE IL VALORE O2 CON I TASTI 8 E 9 PREMERE 11 PER CONFERMARE PREMERE 9 PER CANCELLARE LA CURVA O2 PREMERE 16 ...

Страница 16: ...16 18 0006081092_201305 ITALIANO ESEGUIRE QUESTE OPERAZIONI SU TUTTI I PUNTI DELLA CURVA E PREMERE F3 PER MEMORIZZARE ...

Страница 17: ...8 0006081092_201305 ITALIANO PREMERE 11 PER CANCELLARE TOGLIERE TENSIONE ALLA CENTRALINA PER 20 SEC RIDARE TENSIONE PREMERE F3 DUE VOLTE PREMERE 5 7 8 CONTEMPORANEAMENTE PREMERE 11 AGGIORNAMENTO FINE CORSA ...

Страница 18: ...CARE LSBUS ESTERNI ON INTERNI OFF PERSETTAREILBUSSULLESONDE VERIFICAREILCOLLEGAMENTO ELETTRICO PER DECIDERE CHI É ESTERNO O INTERNO UNA VOLTA STABILITO CHI É ESTERNO O INTERNO METTERE IL PONTE COME DA SCHEMA LT2 SONDE DISPLAY OFF ETAMATIC ON ...

Страница 19: ...manual and are exclusively addresses to qualified personnel See the complete user manual available on Baltur website for further details on other aspects unit use and relative precautions Information contained in this catalogue is not binding The manufacturer reserves the right to change the technical data and any other data it contains INVERTER PARAMETERS PRESET BY BALTUR 7 INSERT A NEW CURVE 8 M...

Страница 20: ...0 mA signal 758 Post ventilation 0 off max 1 000 seconds 774 pilot 0 off 1 on 775 pilot 0 off 1 on 780 pilot time 783 flame stabilization time 787 maintenence mode 1 to adjust pilot 790 load regulator 0 off 1 on 2 with external probe note in calibration mode it is automatically turned off 791 cold start set point temperature or pressure value at boiler exit 0 no function 792 200 start up power loa...

Страница 21: ...r ENTER call Off set will appear and the system will undergo calibration when MEASURE appears the probe will be calibrated EXIT CALIBRATING THE O2 PROBE WITH THE BURNER IN OPERATION Once combustion has been regulated set the burner to about 2 O2 Use the LT2 keyboard CALL START CALL ENTER calibration test with reference measuring ENTER Use the keys to change the O2 values comparing them with those ...

Страница 22: ...OTES PAR N DIGIT ETAMATIC PARAMETERS Try to have the same flow difference between one pint and another P9 P1 8 Potentiometer digit adjustment Gas servomotor min max Air servomotor min max PAR N DIGIT PAR N DIGIT PAR N DIGIT During operation with light oil maintain a good excess of air in the chimney O2 5 6 Check the level of smoke with the minimum and maximum thermal output of the burner using a B...

Страница 23: ...8 0006081092_201305 ENGLISH INVERTER PARAMETERS PRESET BY BALTUR MOTOR PLATE DATA 9905 9906 9907 9908 9909 1003 1 1104 30 1105 50 1201 0 1301 20 check that the jumper is in I position signal current 4 20mA ...

Страница 24: ...8 18 0006081092_201305 ENGLISH MAIN PAGE PRESS 5 7 8 AT THE SAME TIME PRESS 11 TO CONFIRM YOU ACCESS LEVEL 1 PRESS F3 TWICE PRESS 11 TO CONFIRM CANCELLED WILL APPEAR INSERT A NEW CURVE ...

Страница 25: ...05 ENGLISH PRESS F2 ONCE CLOSE THE THERMOSTAT LINE AND WAIT WHEN PLEASE SET IGNITION POINT APPEARS PRESS BUTTON 16 CHECK THE IGNITION LOAD 2 SZP PRESS 16 SET THE IGNITION POINT USING BUTTONS FROM 2 TO 9 PRESS 11 TO CONFIRM ...

Страница 26: ...ONFIRM NOW THE BURNER IS ON CHECK THE COMBUSTION PRESS 17 SET THE MINIMUM LOAD USING BUTTONS 2 AND 3 PRESS 16 SET THE BURNER MINIMUM POWER CHECK THE COMBUSTION AFTER SETTING THE MINIMUM POINT USING BUTTONS FROM 2 TO 9 PRESS 11 TO CONFIRM PRESS 17 ...

Страница 27: ...06081092_201305 ENGLISH SET THE MAXIMUM LOAD USING BUTTONS 2 AND 3 PRESS 16 AFTER SETTING THE MAXIMUM POINT USING BUTTONS FROM 2 TO 9 PRESS 11 TO CONFIRM MODIFY THE LOAD USING BUTTONS 2 AND 3 PRESS 16 PRESS 17 ...

Страница 28: ...12 18 0006081092_201305 ENGLISH ADJUST THE POINT COMBUSTION USING BUTTONS FROM 2 TO 9 PRESS 11 CHECK THE COMBUSTION IN ALL CURVE POINTS 2 200 300 400 500 600 700 800 900 990 STORE USING F2 ...

Страница 29: ...5 7 8 AT THE SAME TIME PRESS 11 TO CONFIRM UNLOCK LEVEL 1 PRESS F3 PRESS 16 USING BUTTONS 2 AND 3 MOVE ON THE LOAD VALUE TO MODIFY PRESS 16 USING BUTTONS FROM 2 TO 9 ADJUST THE SELECTED POINT PRESS 11 TO CONFIRM MODIFYING AN EXISTING CURVE ...

Страница 30: ...14 18 0006081092_201305 ENGLISH FOLLOW THIS PROCEDURE FOR THE POINTS YOU WISH TO MODIFY THEN AT THE END PRESS F2 TO STORE PRESS 5 7 8 AT THE SAME TIME PRESS 11 PRESS F2 SET O2 CURVE ...

Страница 31: ... SET THE O2 CURVE BUTTONS 2 3 PRESS 16 SET THE O2 VALUE USING BUTTONS 8 AND 9 PRESS 11 TO CONFIRM PRESS 17 SETTHELOADVALUEUSINGBUTTONS 2 AND 3 PRESS 16 SET THE O2 VALUE USING BUTTONS 8 AND 9 PRESS 11 TO CONFIRM PRESS 9 TO DELETE THE O2 CURVE PRESS 16 ...

Страница 32: ...16 18 0006081092_201305 ENGLISH FOLLOW THESE PROCEDURES ON ALL THE CURVE POINTS AND PRESS F3 TO STORE ...

Страница 33: ...17 18 0006081092_201305 ENGLISH PRESS 11 TO DELETE CUT POWER TO THE UNIT FOR 20 SEC RESTORE POWER PRESS F3 TWICE PRESS 5 7 8 AT THE SAME TIME PRESS 11 END OF STROKE UPDATE ...

Страница 34: ...AL ON INTERNAL OFF TO SET THE BUS ON THE PROBES CHECK THE ELECTRIC CONNECTION TO DECIDE WHICH IS EXTERNAL AND WHICH IS INTERNAL ONCE DECIDED WHICH IS EXTERNAL ANS WICH IS INTERNAL POSITION THE BRIDGE AS IN THE DIAGRAM LT2 PROBES DISPLAY OFF ETAMATIC ON ...

Страница 35: ...sonal cualificado Para información más detallada sobre otras consideraciones para el uso de la central y las precauciones correspondientes consultar el Manual del usuario completo disponible en la página Web Baltur El presente catálogo tiene una finalidad meramente indicativa El fabricante por tanto se reserva cualquier posibilidad de modificación de los datos técnicos y de todo lo indicado en el ...

Страница 36: ... significado de los parámetros del software pulsar al mismo tiempo Ctrl y F1 517 100 campo de la corrección para la regulación definitiva ver el modo TK 718 200 regulador interno 500 para regulación de 3 puntos 0 para señal 4 20 mA 758 Post ventilación 0 excluida máx 1000 segundos 774 piloto 0 excluido 1 activado 775 piloto 0 excluido 1 activado 780 tiempo piloto 783 tiempo estabilización de llama...

Страница 37: ...hm el sistema está listo para el calibrado pulsar CALL START CALIBRATION ENTER off set calibration on ambient air ENTER aparecerá call Off set y el sistema está en calibración Cuando aparezca MEAESURE la sonda estará calibrada EXIT CALIBRADO DE LA SONDA O2 CON QUEMADOR EN FUNCIONAMIENTO Una vez que esté regulada la combustión llevar el quemador al 2 de O2 aproximadamente Operar en el teclado del L...

Страница 38: ...OS ETAMATIC Intentar obtener la misma diferencia de caudal entre un punto y el otro P9 P1 8 Regulación dígit potenciometro Servomotor gas mín máx Servomotor aire mín máx N PAR DÍGIT N PAR DÍGIT N PAR DÍGIT Durante el funcionamiento con gasóleo mantenga un buen nivel de exceso de aire en la chimenea de O2 5 6 Verifique la fumosidad en la potencia térmica mínima y máxima del quemador con la bomba BA...

Страница 39: ...1305 ITALIANO ESPAÑOL PARÁMETROS INVERSOR PRE SELECCIONADOS POR BALTUR DATOS PLACA MOTOR 9905 9906 9907 9908 9909 1003 1 1104 30 1105 50 1201 0 1301 20 verificar que el jumper esté posicionado en I corriente señal 4 20mA ...

Страница 40: ...8 0006081092_201305 ESPAÑOL PANTALLA PRINCIPAL PULSAR 5 7 8 AL MISMO TIEMPO PULSAR 11 PARA CONFIRMAR SE ACCEDE AL NIVEL 1 PULSAR F3 DOS VECES PULSAR 11 PARA CONFIRMAR APARECERÁ CANCELADO AÑADIR NUEVA CURVA ...

Страница 41: ...R F2 UNA VEZ CERRAR LA LÍNEA TERMOSTÁTICA Y ESPERAR CUANDO APAREZCA PLEASE SET IGNITION POINT PULSAR LA TECLA 16 VERIFICAR LA CARGA ENCENDIDO 2 SZP PULSAR 16 ESTABLECER EL PUNTO DE ENCENDIDO UTILIZANDO LAS TECLAS DE 2 A 9 PULSAR 11 PARA CONFIRMAR ...

Страница 42: ...STÁ ENCENDIDO VERIFICAR LA COMBUSTIÓN PULSAR 17 CON L AS TECL AS 2 Y 3 ESTABLECER LA CARGA MÍNIMA PULSAR 16 ESTABLECER LA POTENCIA MÍNIMA DEL QUEMADOR VERIFICAR LA COMBUSTIÓN UNA VEZ ESTABLECIDO EL PUNTO DE MÍNIMA UTILIZANDO LAS TECLAS DE 2 A 9 PULSAR 11 PARA CONFIRMAR PULSAR 17 ...

Страница 43: ...LIANO ESPAÑOL CON L AS TECL AS 2 Y 3 ESTABLECER LA CARGA MÁXIMA PULSAR 16 UNA VEZ ESTABLECIDO EL PUNTO DE MÁXIMA UTILIZANDO LAS TECLAS DE 2 A 9 PULSAR 11 PARA CONFIRMAR CON LAS TECLAS 2 Y 3 MODIFICAR LA CARGA PULSAR 16 PULSAR 17 ...

Страница 44: ...12 18 0006081092_201305 ESPAÑOL REGULAR EL PUNTO EN COMBUSTIÓN CON LAS TECLAS DE 2 A 9 PULSAR 11 VERIFICAR LA COMBUSTIÓN EN CADA PUNTO DE LA CURVA 2 200 300 400 500 600 700 800 900 990 MEMORIZAR CON F2 ...

Страница 45: ...O TIEMPO PULSAR 11 PARA CONFIRMAR DESBLOQUEO NIVEL 1 PULSAR F3 PULSAR 16 CON L AS TECL AS 2 Y 3 SELECCIONAR EL VALOR DE CARGA A MODIFICAR PULSAR 16 CON LAS TECLAS 2 Y 9 AJUSTAR EL PUNTO QUE SE HASELECCIONADO PULSAR 11 PARA CONFIRMAR MODIFICAR UNA CURVA EXISTENTE ...

Страница 46: ...14 18 0006081092_201305 ESPAÑOL EJECUTAR ESTA OPERACIÓN PARA LOS PUNTOS QUE SE QUIERA MODIFICAR AL FINAL PULSAR F2 PARA MEMORIZAR PULSAR 5 7 8 AL MISMO TIEMPO PULSAR 11 PULSAR F2 ESTABLECER LA CURVA O2 ...

Страница 47: ... CURVA O2 TECLAS 2 3 PULSAR 16 CONLASTECLAS 8 Y 9 ESTABLECER EL VALOR 02 PULSAR 11 PARA CONFIRMAR PULSAR 17 ESTABLECER EL VALOR DE CARGA CON LAS TECLAS 2 Y 3 PULSAR 16 ESTABLECER EL VALOR O2 CON LAS TECLAS 8 Y 9 PULSAR 11 PARA CONFIRMAR PULSAR 9 PARA BORRAR LA CURVA O2 PULSAR 16 ...

Страница 48: ...16 18 0006081092_201305 ESPAÑOL REALIZAR ESTAS OPERACIONES EN TODOS LOS PUNTOS DE LA CURVA Y PULSAR F3 PARA MEMORIZAR ...

Страница 49: ...6081092_201305 ITALIANO ESPAÑOL PULSAR 11 PARA BORRAR QUITAR TENSIÓN A LA CENTRAL PARA 20 SEG VOLVER A TRANSMITIR TENSIÓN PULSAR F3 DOS VECES PULSAR 5 7 8 AL MISMO TIEMPO PULSAR 11 ACTUALIZACIÓN FINAL DE CARRERA ...

Страница 50: ...OS ON INTERNOS OFF PARA PROGRAMAR EL BUS EN LAS SONDAS VERIFICAR LA CONEXIÓN ELÉCTRICA PARA DECIDIR CUÁL ES EXTERNO O INTERNO UNA VEZ ESTABLECIDO CUÁL ES EXTERNO O INTERNO COLOCAR EL PUENTE COMO ILUSTRADO EN EL ESQUEMA LT2 SONDAS PANTALLA OFF ESTAMATIC ON ...

Страница 51: ...nt au personnel qualifié Pour des informations détaillées sur l utilisation du boîtier électronique et les précautions correspondantes consulter le Manuel de l utilisateur complet disponible sur le site Baltur Ce manuel revêt caractère purement indicatif Le constructeur se réserve donc la faculté de modifier les données techniques et tout ce qui est indiqué dans le catalogue PARAMÈTRES INVERSEUR P...

Страница 52: ... 100 champ de la correction pour le réglage définitif voir le mode TK 718 200 régulateur interne 500 pour réglage à 3 points 0 pour signal 4 20 mA 758 Post ventilation 0 désactivée max 1000 secondes 774 pilote 0 désactivé 1 activé 775 pilote 0 désactivé 1 activé 780 temps pilote 783 temps stabilisation de flamme 787 maintenence mode 1 pour régler le pilote 790 régulateur de charge 0 désactivé 1 ac...

Страница 53: ...ance est stable et 100 ohms le système est prêt au calibrage appuyer sur CALL START CALIBRATION ENTER off set calibration on ambient air ENTER call Off set s affichera et le système est en cours de calibrage lorsque MEASURE s affiche la sonde est calibrée EXIT RÉGLAGE DE LA SONDE O2 AVEC BRÛLEUR EN FONCTIONNEMENT Une fois la combustion réglée amener le brûleur à 2 de O2 environ Opérer depuis le cl...

Страница 54: ...EMARQUES N PAR DIGIT PARAMÈTRES ETAMATIC Essayer d obtenir une différence de débit entre un point et l autre P9 P1 8 Réglage digit potentiomètre Servomoteur gaz min max Servomoteur air min max N PAR DIGIT N PAR DIGIT N PAR DIGIT En cours de fonctionnement au fioul garder un excès d air correct à la cheminée O2 5 6 Vérifier les fumées à la puissance minimale et maximale du brûleur au moyen de la po...

Страница 55: ...5 FRANÇAIS PARAMÈTRES INVERSEUR PRÉRÉGLÉS PAR BALTUR DONNÉES DE LA PLAQUETTE SIGNALÉTIQUE DU MOTEUR 9905 9906 9907 9908 9909 1003 1 1104 30 1105 50 1201 0 1301 20 vérifier que le jumper est placé en I courant signal 4 20mA ...

Страница 56: ... FRANÇAIS PAGE ÉCRAN PRINCIPALE APPUYER SUR 5 7 8 SIMULTANÉMENT APPUYERSUR11POURCONFIRMER ON ACCÈDE AU NIVEAU 1 APPUYER SUR F3 DEUX FOIS A P P U Y ER S U R 11 P O U R CONFIRMER EFFACÉ SERA AFFICHÉ SAISIR UNE COURBE NOUVELLE ...

Страница 57: ...A LIGNE THERMOSTATIQUE ET ATTENDRE LORSQUE PLEASE SET IGNITION POINT S AFFICHERA APPUYER SUR LA TOUCHE 16 VÉRIFIER LA CHARGE D ALLUMAGE 2 SZP APPUYER SUR 16 P R O G R A M M E R L E P O I N T D ALLUMAGE EN UTILISANT LES TOUCHES DE 2 À 9 APPUYER SUR 11 POUR CONFIRMER ...

Страница 58: ...MÉ VÉRIFIER LA COMBUSTION APPUYER SUR 17 À L AIDE DES TOUCHES 2 ET 3 PROGRAMMER LA CHARGE MINIMUM APPUYER SUR 16 PROGRAMMER LA PUISSANCE MINIMALE DU BRÛLEUR VÉRIFIER LA COMBUSTION UNE FOIS LE POINT DE MINIMUM PROGRAMMÉ EN UTILISANT LES TOUCHES DE 2 À 9 APPUYERSUR 11 POURCONFIRMER APPUYER SUR 17 ...

Страница 59: ...DE DES TOUCHES 2 ET 3 PROGRAMMERLACHARGEMAXIMUM APPUYER SUR 16 UNE FOIS LE POINT DE MAXIMUM PROGRAMMÉ EN UTILISANT LES TOUCHES DE 2 À 9 APPUYERSUR 11 POURCONFIRMER À L AIDE DES TOUCHES 2 ET 3 MODIFIER LA CHARGE APPUYER SUR 16 APPUYER SUR 17 ...

Страница 60: ...1092_201305 FRANÇAIS RÉGLER EN COURS DE COMBUSTION À L AIDE DES TOUCHES DE 2 À 9 LE POINT APPUYER SUR 11 VÉRIFIERLACOMBUSTIONDANSTOUS LES POINTS DE LA COURBE 2 200 300 400 500 600 700 800 900 990 MÉMORISER AVEC F2 ...

Страница 61: ...R SUR 11 POUR CONFIRMER DÉBLOCAGE NIVEAU 1 APPUYER SUR F3 APPUYER SUR 16 À L AIDE DES TOUCHES 2 ET 3 ATTEINDRELAVALEURDELACHARGE À MODIFIER APPUYER SUR 16 À L AIDE DES TOUCHES DE 2 À 9 RÉGLER LE POINT SÉLECTIONNÉ APPUYER SUR 11 POUR CONFIRMER MODIFIER UNE COURBE EXISTANTE ...

Страница 62: ...081092_201305 FRANÇAIS EFFECTEUR CETTE OPÉRATION POUR LES POINTS QUE L ON VEUT MODIFIER À LA FIN APPUYER SUR F2 POUR MÉMORISER APPUYER SUR 5 7 8 SIMULTANÉMENT APPUYER SUR 11 APPUYER SUR F2 PROGRAMMER LA COURBE O2 ...

Страница 63: ...6 À L AIDE DES TOUCHES 8 ET 9 PROGRAMMER LA VALEUR DE O2 APPUYER SUR 11 POUR CONFIRMER APPUYER SUR 17 PROGRAMMER LA VALEUR DE LA CHARGE À L AIDE DES TOUCHES 2 ET 3 APPUYER SUR 16 PROGRAMMERLAVALEURO2ÀL AIDE DES TOUCHES 8 ET 9 APPUYER SUR 11 POUR CONFIRMER APPUYERSUR 9 POUREFFACER LA COURBE O2 APPUYER SUR 16 ...

Страница 64: ...16 18 0006081092_201305 FRANÇAIS EFFECTUER CETTE OPÉRATION SUR TOUS LES POINTS DE LA COURBE ET APPUYER SUR F3 POUR MÉMORISER ...

Страница 65: ..._201305 FRANÇAIS APPUYER SUR 11 POUR EFFACER COUPER LA TENSION AU BOÎTIER ÉLECTRONIQUE PENDANT 20 S RÉTABLIR LA TENSION APPUYER SUR F3 DEUX FOIS APPUYER SUR 5 7 8 SIMULTANÉMENT APPUYER SUR 11 MISE À JOUR FIN DE COURSE ...

Страница 66: ... LSBUS EXTÉRIEURS ON INTÉRIEURS OFF POURPROGRAMMERLEBUSDESSONDES VÉRIFIERLACONNEXION ÉLECTRIQUE POUR ÉTABLIR L EXTÉRIEUR ET L INTÉRIEUR UNE FOIS L EXTÉRIEUR ET L INTÉRIEUR ÉTABLIS METTRE LE PONT SELON LE SCHÉMA LT2 SONDES ÉCRAN OFF ETAMATIC ON ...

Страница 67: ...er konular hakkındaki detaylı bilgiler için Baltur sitesinde bulunan KUllanıcı Kılavuzuna bakınız Bu katalog sadece bilgilendirme amaçlıdır Üretici firma bu nedenle teknik verileri ve burada aktarılan diğer bilgileri değiştirme hakkını saklı tutar OPERATING UNIT ARACILIĞI İLE ETAMATIC ÜNİTESİNİN PROGRAMLANMASI KILAVUZU güncelleme 14 Şubat 08 4 CO KONTROLLÜ ETAMATIC HIZLI PROGRAMLAMA KILAVUZU Seviy...

Страница 68: ...anda Crtl ve F1 e basınız 517 100 düzeltme alanı nihai ayar için bakınız TK prosedürü 718 200 dahili regülatör 500 3 noktalı ayar için 0 4 20 mA sinyali için 758 Art havalandırma 0 kapalı azami 1000 saniye 774 pilot 0 kapalı 1 açık 775 pilot 0 kapalı 1 açık 780 pilot süresi 783 alev dengeleme süresi 787 bakım modu 1 pilotu ayarlamak için 790 yük regülatörü 0 kapalı 1 açık 2 harici sonda ile not ka...

Страница 69: ...TER off set calibration on ambient air ENTER call Off set görünecektir ve sistem kalibrasyonda olacaktır MEAESURE görüntülendiğinde sonda kalibre edilmiştir EXIT BRÜLÖR ÇALIŞIR VAZİYETTEYKEN O2 SONDASI KALİBRASYONU Yanma ayarlandıktan sonra brölürü yaklaşık olarak 2 lik O2 ye getiriniz LT2 nin klavyesini kullanınız CALL START CALL ENTER calibration test with reference measuring ENTER tuşlarını kul...

Страница 70: ...TRELERİ İki nokta P9 P1 8 arasında aynı kapasite farkını elde etmeye çalışın Dijit potansiyometre ayarı Gaz servomotoru asgari azami Hava servomotoru asgari azami PAR NO DIGIT PAR NO DIGIT PAR NO DIGIT D i z e l l e ç a l ı ş m a s ı e s n a s ı n d a b a c a d a hava fazlalığı muhafaza ediniz O2 5 6 O2sondasınınzarargörmesiniönlemekamacıile BACHARA pompasını kullanarak brülörün asgari ve azami te...

Страница 71: ...92_201305 TÜRKÇE BALTUR TARAFINDAN GİRİLEN INVERTER PARAMETRELERİ MOTOR ETİKET VERİLERİ 9905 9906 9907 9908 9909 1003 1 1104 30 1105 50 1201 0 1301 20 jumperin I konumunda olmasına dikkat ediniz sinyal akımı 4 20mA ...

Страница 72: ...1305 TÜRKÇE ANA EKRAN AYNI ANDA 5 7 VE 8 E BASINIZ ONAYLAMAK İÇİN 11 E BASINIZ SEVİYE 1 E ERİŞİLİR F3 E İKİ DEFA BASINIZ ONAYLAMAK İÇİN 11 E BASINIZ CANCELLATO SİLİNDİ İBARESİ GÖRÜNTÜLENECEKTİR YENİ BİR EĞRİNİN GİRİLMESİ ...

Страница 73: ...A BASINIZ TERMO STATİK HATTI KAPATINIZ VE BEKLEYİNİZ PLEASE SET IGNITION POINT GÖRÜNTÜLENDİĞİNDE 16 YA BASINIZ YANMA YÜKÜNÜ 2 SZP KONTROL EDİNİZ 16 YA BASINIZ 2 İLA 9 AR ASI TUŞLARI KULLANARAK YANMA NOKTASINI GİRİNİZ ONAYLAMAK İÇİN 11 E BASINIZ ...

Страница 74: ...ÖR ÇALIŞMAKTADIR YANMAYI KONTROL EDİNİZ 17 YE BASINIZ 2 VE 3 TUŞLARI İLE ASGARİ YÜKÜ GİRİNİZ 16 YE BASINIZ BRÜLÖRÜN ASGARİ GÜCÜNÜ GİRİNİZ YANMAYI KONTROL EDİNİZ 2 İ LA 9 ARASI TUŞLARI KULLANARAK ASGARİ NOKTAYI AYARLADIKTAN SONRA ONAYLAMAK İÇİN 11 E BASINIZ 17 YA BASINIZ ...

Страница 75: ... TÜRKÇE 2 VE 3 TUŞLARI İLE AZAMİ YÜKÜ GİRİNİZ 16 YA BASINIZ 2 İ LA 9 ARASI TUŞLARI KULLANARAK AZAMİ NOKTAYI AYARLADIKTAN SONRA ONAYLAMAK İÇİN 11 E BASINIZ 2 VE 3 TUŞLARI İLE AZAMİ YÜKÜ DEĞİŞTİRİMİZ 16 YA BASINIZ 17 YA BASINIZ ...

Страница 76: ...8 0006081092_201305 TÜRKÇE YANMADA NOKTAYI 2 VE 9 ARASI TUŞLAR İLE AYARLAYINIZ 1 E BASINIZ 2 200 300 400 500 600 700 800 900 990 EĞRİSİNİN TÜM NOKTALARINDA YANMAYI KONTROL EDİNİZ F2 İLE HAFIZAYA KAYDEDİNİZ ...

Страница 77: ...IZ ONAYLAMAK İÇİN 11 E BASINIZ SEVİYE 1 SERBEST F3 E BASINIZ 16 YA BASINIZ 2 VE 3 TUŞLARIİLEDEĞİŞTİRİLECEK YÜK DEĞERİNE GELİNİZ 16 YA BASINIZ 2 İLA 9 ARASI TUŞLAR İLE SEÇİLEN NOKTAYI DEĞİŞTİRİNİZ ONAYLAMAK İÇİN 11 E BASINIZ MEVCUT BİR EĞRİDE DEĞİŞİKLİK YAPMAK ...

Страница 78: ...4 18 0006081092_201305 TÜRKÇE BUİŞLEMİDEĞİŞTİRİLECEKNOKTALAR İÇİN GERÇEKLEŞTİRİNİZ SONUNDA HAFIZAYA KAYDETMEK İÇİN F2 YE BASINIZ AYNIANDA 5 7 VE 8 EBASINIZ 11 E BASINIZ F2 YE BASINIZ O2 EĞRİSİNİ GİRİNİZ ...

Страница 79: ...Z TUŞLAR 2 3 16 E BASINIZ 8 VE 9 TUŞLARI İLE O2 DEĞERİNİ GİRİNİZ ONAYLAMAK İÇİN 11 E BASINIZ 17 E BASINIZ YÜK DEĞERİNİ 2 VE 3 TUŞLARI İLE GİRİNİZ 16 E BASINIZ O2 DEĞERİNİ 8 VE 9 TUŞLARI İLE GİRİNİZ ONAYLAMAK İÇİN 11 E BASINIZ O2 EĞRİSİNİ SİLMEK İÇİN 9 A BASINIZ 16 YA BASINIZ ...

Страница 80: ...16 18 0006081092_201305 TÜRKÇE BU İŞLEMLERİ EĞRİNİN TÜM NOKTALARINDA TEKRAR EDİNİZ VE HAFIZAYA ALMAK İÇİN F3 BASINIZ ...

Страница 81: ...17 18 0006081092_201305 TÜRKÇE SİLMEK İÇİN 11 E BASINIZ ÜNİTENİN AKIMINI 20 SANİYE BOYUNCA KESİNİZ AKIMI GERİ VERİNİZ F3 E İKİ DEFA BASINIZ AYNIANDA 5 7 VE 8 EBASINIZ 11 E BASINIZ KURS SONU GÜNCELLEME ...

Страница 82: ... OFF SONDALARIN ÜZERİNDEKİ BUS U AYARLAMAK İÇİN HANGİSİNİN HARİCİ HANGİSİNİN DAHİLİ OLDUĞUNA KARAR VERMEK İÇİN ELEKTRİK BAĞLANTISINI KONTROL EDİNİZ HARİCİ VE DAHİLİLERE KARAR VERİLDİKTEN SONRA ŞEMADA GÖSTERİLDİĞİ ÜZERE KÖPRÜYUÜ YERLEŞTİRİNİZ LT2 SONDALAR EKRAN OFF ETAMATIC ON ...

Страница 83: ...персонала Для получения подробной информации по другим аспектам по применению контроллера и принятию соответствующих мер предосторожности обращайтесь к инструкции пользователя Настоящий каталог носит исключительно информативный ориентировочный характер Следовательно изготовитель оставляет за собой все права на внесение изменений в технические данные и другие приведенные здесь характеристики ПРЕДВА...

Страница 84: ...вертора соответствует параметру P 517 CH4 100 если коррекция применяется для воздушного сервопривода соответствует параметру P 517 Parameter Only Enabled для отображения значения параметров программного обеспечения нажмите Ctrl и F1 517 100 диапазон коррекции для окончательного вида режима настройки TK 718 200 внутренний регулятор 500 для 3 позиционного управления 0 для сигнала 4 20 мА 758 последу...

Страница 85: ...ЛИБРОВКА ЗОНДА О2 Посредством дисплея щита контроля кислорода соединитесь с дистанционной системой CO Нажмите DIAG REMOTE BREAKCONNECTION ENTER EXIT EXIT Проверьте что значение напряжения зонда О2 в мВ отрицательное в противном случае инвертируйте провода 33 и 34 Когда сопротивление стабильное и 100 Ом система готова к калибровке нажмите CALL START CALIBRATION ENTER off set calibration on ambient ...

Страница 86: ...АЗРЯД ПАРАМЕТРЫ ЕТАМATIC Попытайтесь сделать так чтобы разница в расходе между двумя точками была одинаковой P9 P1 8 Регулировка разряда потенциометра Газовый сервопривод мин макс Воздушный сервопривод мин макс ПАР N РАЗРЯД ПАР N РАЗРЯД ПАР N РАЗРЯД Во время работы в дизельных горелках поддерживает необходимый избыток воздуха в дымоходе O2 5 6 Проверьте дымность при максимальной и минимальной тепл...

Страница 87: ...305 РУССКИЙ ПРЕДВАРИТЕЛЬНО ЗАДАННЫЕ ПАРАМЕТРЫ ИНВЕРТОРА BALTUR ДАННЫЕ ТАБЛИЧКИ ДВИГАТЕЛЯ 9905 9906 9907 9908 9909 1003 1 1104 30 1105 50 1201 0 1301 20 проверьте что перемычка находится в положении I токовый сигнал 4 20мА ...

Страница 88: ...92_201305 РУССКИЙ ГЛАВНЫЙ ЭКРАН НАЖМИТЕ 5 7 8 ОДНОВРЕМЕННО НАЖ М ИТЕ 1 1 Д Л Я ПОДТВЕРЖДЕНИЯ ПОЛУЧИТЕ ДОСТУП К УРОВНЮ 1 НАЖМИТЕ F3 ДВАЖДЫ НАЖ М ИТЕ 1 1 Д Л Я ПОДТВЕРЖДЕНИЯ ПОЯВЛЯЕТСЯ CANCELLATO ВВЕДИТЕ НОВУЮ КРИВУЮ ...

Страница 89: ...ДИН РАЗ ЗАМКНИТЕ КОНТУР ТЕРМОДАТЧИКА И ОЖИДАЙТЕ КОГДА ПОЯВИТСЯ PLEASE SET IGNITION POINT НАЖМИТЕ КНОПКУ 16 ПРОВЕРЬТЕ НАГРУЗКУ ЗАЖИГАНИЯ 2 SZP НАЖМИТЕ 16 УСТАНОВИТЕ ТОЧКУ ЗАЖИГАНИЯ ИСПОЛЬЗУЯ КНОПКИ ОТ 2 ДО 9 Н А Ж М И Т Е 1 1 Д Л Я ПОДТВЕРЖДЕНИЯ ...

Страница 90: ...ЕЙЧАС ГОРЕЛКА ГОРИТ ПРОВЕРЬТЕ ГОРЕНИЕ НАЖМИТЕ 17 КНОПКАМИ 2 И 3 УСТАНОВИТЕ МИНИМАЛЬНУЮ НАГРУЗКУ НАЖМИТЕ 16 УСТАНОВИТЕ МИНИМА ЛЬНУЮ МОЩНОСТЬ ГОРЕЛКИ ПРОВЕРЬТЕ ГОРЕНИЕ УСТАНОВИТЕОДИНРАЗТОЧКУМИНИМУМА ИСПОЛЬЗУЯ КНОПКИ ОТ 2 ДО 9 НАЖ М ИТЕ 1 1 Д Л Я ПОДТВЕРЖДЕНИЯ НАЖМИТЕ 17 ...

Страница 91: ... РУССКИЙ КНОПКАМИ 2 И 3 УСТАНОВИТЕ МИНИМАЛЬНУЮ НАГРУЗКУ НАЖМИТЕ 16 УСТАНОВИТЕ ОДИН РАЗ ТОЧКУ МАКСИМУМА ИСПОЛЬЗУЯ КНОПКИ ОТ 2 ДО 9 НАЖМИТЕ 11 ДЛЯПОДТВЕРЖДЕНИЯ КНОПКАМИ 2 И 3 ИЗМЕНИТЕ МИНИМАЛЬНУЮ НАГРУЗКУ НАЖМИТЕ 16 НАЖМИТЕ 17 ...

Страница 92: ...12 18 0006081092_201305 РУССКИЙ О ТРЕ Г У Л ИРУ Й ТЕ Г О РЕНИЕ КНОПКАМИ ОТ 2 ДО 9 В ТОЧКЕ НАЖМИТЕ 11 ПРОВЕРЬТЕ ГОРЕНИЕ ВО ВСЕХ ТОЧКАХ КРИВОЙ 2 200 300 400 500 600 700 800 900 990 ЗАПОМНИТЬ F2 ...

Страница 93: ...ТЕ 1 1 Д Л Я ПОДТВЕРЖДЕНИЯ ДЕБЛОКИРОВКА УРОВНЯ 1 НАЖМИТЕ F3 НАЖМИТЕ 16 КНОПКАМИ 2 И 3 ВВЕДИТЕ З НАЧ ЕНИЕ НА Г РУ З К И Д Л Я ИЗМЕНЕНИЯ НАЖМИТЕ 16 К Н О П К А М И О Т 2 Д О 9 СИСТЕМАТИЗИРУЙТЕВЫБРАННЫЕТОЧКИ НАЖ М ИТЕ 1 1 Д Л Я ПОДТВЕРЖДЕНИЯ ИЗМЕНЕНИЕ СУЩЕСТВУЮЩЕЙ КРИВОЙ ...

Страница 94: ...14 18 0006081092_201305 РУССКИЙ ВЫПОЛНИТЕ ЭТУ ОПЕРАЦИЮ ДЛЯ ТОЧЕК КОТОРЫЕ ВЫ ХОТИТЕ ИЗМЕНИТЬ В КОНЦЕ НАЖМИТЕ F2 ДЛЯ ЗАПОМИНАНИЯ НАЖ М ИТЕ 5 7 8 ОДНОВРЕМЕННО НАЖМИТЕ 11 НАЖМИТЕ F2 УСТАНОВИТЕ КРИВУЮ O2 ...

Страница 95: ...O2 КНОПКИ 2 3 НАЖМИТЕ 16 КНОПКАМИ 8 И 9 УСТАНОВИТЕ ЗНАЧЕНИЕ ДЛЯ O2 НАЖ М ИТЕ 1 1 Д Л Я ПОДТВЕРЖДЕНИЯ НАЖМИТЕ 17 УСТАНОВИТЕ ЗНАЧЕНИЕ НАГРУЗКИ КНОПКАМИ 2 И 3 НАЖМИТЕ 16 УСТАН О В ИТЕ ЗНАЧ ЕНИЕ O 2 КНОПКАМИ 8 И 9 НАЖ М ИТЕ 1 1 Д Л Я ПОДТВЕРЖДЕНИЯ НАЖМИТЕ 9 ДЛЯ ОТМЕНЫ КРИВОЙ O2 НАЖМИТЕ 16 ...

Страница 96: ...16 18 0006081092_201305 РУССКИЙ ВЫПОЛНИТЕ ЭТИ ОПЕРАЦИИ НА ВСЕХ ТОЧКАХ КРИВОЙ И НАЖМИТЕ F3 ДЛЯ ЗАПОМИНАНИЯ ...

Страница 97: ...17 18 0006081092_201305 РУССКИЙ НАЖ М ИТЕ 1 1 Д Л Я ПОДТВЕРЖДЕНИЯ ОТКЛЮЧИТЕ ПИТАНИЕ К БЛОКУ ДЛЯ 20 СЕК ОБРАТНОЕ НАПРЯЖЕНИЕ НАЖМИТЕ F3 ДВАЖДЫ НАЖ М ИТЕ 5 7 8 ОДНОВРЕМЕННО НАЖМИТЕ 11 ОБНОВЛЕНИЕ КОНЦА ХОДА ...

Страница 98: ...ШНИЕ ВКЛЮЧЕНЫ ВНУТРЕННИЕ ВЫКЛЮЧЕНЫ ДЛЯ УСТАНОВКИ ЗОНДА ШИНЫ ПРОВЕРЬТЕ ЭЛЕКТРИЧЕСКОЕ СОПРОТИВЛЕНИЕ ДЛЯ ПРИНЯТИЯ РЕШЕНИЯ ВНУТРИ ИЛИ СНАРУЖИ ОДИН РАЗ УСТАНОВИТЬ СНАРУЖИ ИЛИ ВНУТРИ РАСПОЛОЖЕНА ТОЧКА ПРИНАДЛЕЖАЩАЯ СХЕМЕ LT2 ЗОНД ДИСПЛЕЙ ВЫКЛЮЧЕН ETAMATIC ВКЛЮЧЕН ...

Страница 99: ...性操作 用于燃烧传感器 检测与控制 其中的信息不可替代用户手册 且仅供有资格的人员使用 关于本设备的使用和相关预防措施的 其他详细信息 请参阅 Baltur 网站上完整的 用户手册 该目录仅供参考 因此 我们保留变更技术数据的一切权力 而不予另行通知 用 操作装置 对 ETAMATIC 设备进行设置的快速指南 2008 年 2 月 14 日更新 4 1 级 CO 控制 ETAMATIC 编程快速指南 O2 和 CO 传感器校准 5 由 BALTUR 预设的开关参数 7 导入一条新曲线 8 修改现有曲线 13 设置 O2 曲线 14 行程开关的更新 17 检查 LSBUS 18 ...

Страница 100: ...18 200 内部调节器 500 用于 3 点调 节 0 用于 4 20 mA 的信号 758 后通风 0 断开 最多 1000 秒 774 引导 0 断开 1 接通 775 引导 0 断开 1 接通 780 引导时间 783 火焰稳定化的时间 787 维护保养模式 1 调节引导 790 负载调节器 0 断开 1 接通 2 具有外部传感器 注 在 校准 模式下自动断开 791 从冷却状态开始的设置点 0 无运行 792 200 运行功率 在该载荷时燃烧器在冷却状态下开始 运行 0 无运行 793 启动时间 最大 从启动功率 P 792 到最大功率 所用的时间 秒 0 无运行 796 设置点 在 50 到 24 之间接触器断开 锅炉出口的 温度值或压力值 797 具有外部传感器的设置点 参见 P 800 和 P 801 798 第 2 设置点 在 50 到 24 之间接触器闭合 比 如 夜间...

Страница 101: ...果不是则调 换电线 33 和 34 当电阻稳定且 100 ohm 时 该系统已经为校准做好了准 备 按 CALL START CALIBRATION ENTER off set calibration on ambient air ENTER 将显示 call Off set 且本系统进入校准 当显示 MEAESURE 时传感 器即校准完毕 EXIT 在燃烧器运行中校准 O2 传感器 在调节好燃烧后 将燃烧器设置为约 2 的 O2 在 LT2 的键盘上操作 CALL START CALL ENTER calibration test with reference measuring ENTER 使用按键 调节 O2 的数值 同时与便携工具上测量到 的数值进行对比 ENTER 在燃烧器运行中校准 CO 传感器 TK 模式 插入参数 P896 1 O2 调节器接通 在燃烧器点燃的情况下 STA...

Страница 102: ...无矫 正CO 有矫 正CO P0 点火 ZP 2 P1 最小 200 P2 300 P3 400 P4 500 P5 600 P6 700 P7 800 P8 900 P9 最大 990 用户 注 参数号 数字 ETAMATIC 参数 试图得到点与点之间同样的差值 P9 P1 8 电位计的数字调整 燃气伺服电机 最小 最大 空气伺服电机 最小 最大 参数号 数字 参数号 数字 参数号 数字 在 使 用 轻 油 的 运 行 过 程 中 维 持 烟 道 中 的 空 气 充 足 O 2 5 6 检查燃烧器最小热功率和最大热功率时的烟 其 中使用 BACHARA 泵 以避免损坏 O2 传感器 PID 参数表 调节类型 P 805 P P 806 I 秒 P 807 I 秒 非常慢 30 400 10 慢 15 320 40 正常 7 90 50 快 4 35 17 非常快 40 55 15 在使用...

Страница 103: ...7 18 0006081092_201305 ESPAÑOL 中 文 由 BALTUR 预设的开关参数 电机标牌数据 9905 9906 9907 9908 9909 1003 1 1104 30 1105 50 1201 0 1301 20 检查确保跳线在位置 I 信号电流 4 20 mA ...

Страница 104: ...8 18 0006081092_201305 ESPAÑOL 中 文 主屏幕 同时按 5 7 8 按 11 确认 进入第 1 级 按 F3 两次 按 11 确认 显示 CANCELLATO 已删除 导入一条新曲线 ...

Страница 105: ...9 18 0006081092_201305 ESPAÑOL 中 文 按 F2 一次 闭合温度开关线路并等待 当显示 PLEASE SET IGNITION POINT 请设置点 火点 时按按钮 16 检查点火负载 2 SZP 按 16 用从 2 到 9 这几个键设置 点火点 按 11 确认 ...

Страница 106: ...10 18 0006081092_201305 ESPAÑOL 中 文 按 11 确认 现在燃烧器已点燃 检查燃烧情况 按 17 用键 2 和 3 设置最小负载 按 16 设置燃烧器的最低功率 检查燃烧 情况 在用从 2 到 9 这几个键设置最 低点之后 按 11 确认 按 17 ...

Страница 107: ...11 18 0006081092_201305 ESPAÑOL 中 文 用键 2 和 3 设置最大负载 按 16 在用从 2 到 9 这几个键设置最 高点之后 按 11 确认 用键 2 和 3 修改最大负载 按 16 按 17 ...

Страница 108: ...12 18 0006081092_201305 ESPAÑOL 中 文 在燃烧过程中用从 2 到 9 这几 个按键调节该点 按 11 在曲线上所有点上检验燃烧情况 2 200 300 400 500 600 700 800 900 990 用 F2 存储记忆 ...

Страница 109: ...13 18 0006081092_201305 ESPAÑOL 中 文 同时按 5 7 8 按 11 确认 关闭第 1 级 按 F3 按 16 用 2 和 3 键设置到要修改的 负载数值 按 16 用从 2 到 9 这几个按键设置 所选的点 按 11 确认 修改现有曲线 ...

Страница 110: ...14 18 0006081092_201305 ESPAÑOL 中 文 对于要修改的各点进行该操作 要 结束则按 F2 存储记忆 同时按 5 7 8 按 11 按 F2 设置 O2 曲线 ...

Страница 111: ...15 18 0006081092_201305 ESPAÑOL 中 文 检查负载以设置 O2 曲线 键 2 3 按 16 用键 8 和 9 设置 O2 值 按 11 确认 按 17 用键 2 和 3 设置负载值 按 16 用键 8 和 9 设置 O2 值 按 11 确认 按 9 来删除 O2 曲线 按 16 ...

Страница 112: ...16 18 0006081092_201305 ESPAÑOL 中 文 对于要曲线各点进行该操作 并按 F3 存储记忆 ...

Страница 113: ...17 18 0006081092_201305 ESPAÑOL 中 文 按 11 删除 切断本设备上的电源 20 秒 重新通电 按 F3 两次 同时按 5 7 8 按 11 行程开关的更新 ...

Страница 114: ...18 18 0006081092_201305 ESPAÑOL 中 文 检查 LSBUS 外部 ON 内部 OFF 要设置各传感器上的 BUS 需检查电气连接以确定哪个是外 部的 哪个是内部的 在确定哪个是外部的或内部的之后 按照电路图进行连接 LT2 传感器 DISPLAY OFF ETAMATIC ON ...

Страница 115: ......

Страница 116: ...ildirilen teknik veriler sadece bilgi amaçlıdır Baltur önceden uyarı yapmaksızın ürünün teknik özelliklerinde değişiklik yapma hakkını saklı tutar Ο παρών κατάλογος διατίθεται για ενημερωτικούς και μόνο σκοπούς Ο κατασκευαστής διατηρεί το δικαίωμα τροποποίησης των τεχνικών δεδομένων και οποιονδήποτε άλλων πληροφοριών κατά την αποκλειστική του κρίση Dane zawarte w tej instrukcji służą tylko i wyłąc...