TECHNICAL SPECIFICATIONS
MODEL
BTG 3,6P
BTG 6P
BTG 11P
MAXIMUM NATURAL GAS HEAT POWER
kW
41.9
56.3
99
MINIMUM NATURAL GAS HEAT POWER
kW
16.3
30.6
48.8
¹) NATURAL GAS EMISSIONS
mg/kWh
Class 2
Class 2
Class 2
OPERATION
Two-stage
Two-stage
Two-stage
NATURAL GAS TRANSFORMER 50 Hz
15kV - 25mA
15kV - 25mA
15kV - 25mA
NATURAL GAS TRANSFORMER 60 Hz
15kV - 25mA
15kV - 25mA
15kV - 25mA
MAXIMUM NATURAL GAS HEAT RATE
Stm³/h
4.2
5.7
10
MINIMUM NATURAL GAS HEAT RATE
Stm³/h
1.6
3.1
4.9
MAXIMUM NATURAL GAS PRESSURE
mbar
360
360
360
NATURAL GAS MINIMUM PRESSURE
mbar
19
20
20
PROPANE GAS MAXIMUM THERMAL POWER
kW
41.9
56.3
99
PROPANE GAS MINIMUM THERMAL POWER
kW
16.3
30.6
48.8
PROPANE GAS MAXIMUM HEAT CAPACITY
Stm³/h
1.63
2.2
3.87
PROPANE GAS MINIMUM HEAT CAPACITY
Stm³/h
0.64
1.2
1.9
PROPANE GAS MAXIMUM PRESSURE
mbar
360
360
360
PROPANE GAS MINIMUM PRESSURE
mbar
30
30
30
²)PROPANE EMISSIONS
mg/kWh
Class 2
Class 2
Class 2
50 Hz FAN MOTOR
kW
0.11
0.11
0.11
50Hz FAN MOTOR RPM
r.p.m.
2800
2800
2800
60Hz FAN MOTOR
kW
0.11
0.11
0.11
60Hz FAN MOTOR RPM
r.p.m.
3300
3300
3300
ABSORBED ELECTRICAL POWER* 50Hz
kW
0.11
0.11
0.11
ABSORBED ELECTRICAL POWER* 60Hz
kW
0.11
0.11
0.11
50 Hz POWER SUPPLY VOLTAGE
1N~ 230V ± 10%
1N~ 230V ± 10%
1N~ 230V ± 10%
60 Hz POWER SUPPLY VOLTAGE
1N~ 220V ± 10%
1N~ 220V ± 10%
1N~ 220V ± 10%
DEGREE OF PROTECTION
IP40
IP40
IP40
FLAME DETECTOR
IONISATION PROBE
IONISATION PROBE
IONISATION PROBE
EQUIPMENT
LME21..
LME21..
LME21..
SOUND PRESSURE**
dBA
64
64
64
WEIGHT WITH PACKING
kg
12
12
12
WEIGHT WITHOUT PACKING
kg
10.75
10.75
10.75
Calorific power lower than reference conditions 15° C, 1013 mbar:
Natural gas: Hi = 9.45 kWh/Stm³ = 34.02 MJ/Stm³
Propane gas: Hi = 24.44 kWh/Stm³ = 88.00 MJ/Stm³
For different types of gas and pressure values, please contact our sales department.
Minimum gas pressure, depending on the type of gas train used for obtaining max. flow rate with null pressure in the combustion cham
-
ber.
* Total absorption at start with ignition transformer on.
The measurements have been carried out in accordance with EN 15036 - 1 standard.
** The acoustic pressure measured with burner operating at maximum rated thermal output refers to the manufacturer's laboratory
environment conditions and cannot be compared to measurements carried out in different locations.
*** Acoustic power was obtained characterizing the manufacturer's laboratory with a sample source; this measurement has a class 2
accuracy (engineering class) with a standard deviation of 1.5 dB(A).
CO emissions, natural gas/propane ≤ 100 mg/kWh
ENGLISH
6 / 30
0006080763_201611
Содержание BTG 3,6P
Страница 2: ......
Страница 31: ...SCHEMI ELETTRICI ITALIANO 29 30 0006080763_201611...
Страница 61: ...WIRING DIAGRAMS ENGLISH 29 30 0006080763_201611...
Страница 63: ......