3.5.1.

 

At battery discharge

 

it is necessary to install new batteries (2 pcs.) of dimension-type D into the battery sec-

tion 14 (see scheme 14), in accordance with polarity, indicated on the internal side of the section

’s coverplate. He indica-

tor  of  battery  discharge  is  the  absence  or  a  sustainable  reduction  of  electric  sparks  
between the ignition plug and burner after the beginning of water flow through the appli-
ance  (with  consumption  not  less  than  2,5  l/min).  In  order  to  open  the  battery  section

’s 

coverplate it is necessary to turn the coverplate’s knob into the position  «ОN». In order 
to  take  the  discharged  elements  out  it  is  necessary  to  unbend  the  holddowns  (shown 
with arrows on scheme 15). 

It is recommended to install alkaline batteries of the type LR20, of increased energy 

output  ratio,  providing  longer  operation  time  of  the  appliance.  Installation  of  low  quality 
batteries or of batteries with low energy output ratio will lead to their rapid discharge and  
loss of the appliance’s function. After installing the batteries it is necessary to close the 
section’s coverplate and turn the coverplate’s knob to the position «ОFF». 

3.5.2.  Battery  replacement  must  be  effectuated  on  the  appliance  when  it  is 

switched off. 

 
 
 

3.6. Protection from freezing 

In case if after switching the appliance off water freezing is possible in it, it is necessary to drain the water out of the 

appliance in the following way: 

а)  Close the gas lock valve and cold water lock valve by the inlet into the appliance; 

b) Open the hot water tap;  
c)Switch the  water consumption regulation knob to the position 

“Maximum consumption”, turn the plug 20 (scheme 

12, 14), let the water drain to a tank and turn back the plug  20 up to the stop; 
d)close the hot water tap. 

3.7. Actions in emergency situations 

In case of emergency situation during the appliance

’s operation it is necessary to:

 

a)  Close the gas stop valve by the inlet into the appliance; 

b)  Close the cold water stop valve by the inlet into the appliance (in case of water leakage appearance); 
c)  Call the special service organization for the 

appliance’s repair. 

ATTENTION! At switching the appliance off by the draught sensor (thermorelay 16, scheme 12, 14) it is nec-

essary to close the hot  water tap and ventilate the premise.  Switching the appliance on the next time would be 
possible after thermorelay’s self-cooling (in 1-2 minutes). In case of repeated shutdowns of the appliance by the 
draught sensor it is necessary to address to a specialized service organization in order to eliminate the failure of 
the gas outlet system. Switching the draught sensor off and incompetent handling of it is unacceptable and can 
cause poisoning with carbonic oxide. 

 

Scheme 6. Battery sec-

tion

 

Содержание NEVA-4511

Страница 1: ...ment Ltd The telephone number of the unified technical support Service is 8 800 555 40 35 free call on the territory of Russian Federation working hours of the service twenty four hour The installatio...

Страница 2: ...ance 15 7 10 Rendering the appliance to another type and pressure of gas 15 8 CONSTRUCTION AND OPERATION CONTROL OF THE APPLIANCE 15 8 1 Construction of the appliance BaltGaz NEVA 4511 15 8 4 Operatio...

Страница 3: ...fore the failure is eliminated 1 4 In case of the appliance s normal operation and in case if the gas pipeline is failure free there must not be the smell of gas in the premise IN CASE IF YOU FEEL THE...

Страница 4: ...2 2 6 Rated gas pressure kPa mm w g natural G20 2 nd family group liquefied G30 3 rd family group 1 3 130 2 0 200 2 9 300 2 2 7 Rated gas consumption natural m 3 h liquefied kg h 2 2 1 66 2 2 8 Rated...

Страница 5: ...nation Name Quantity pcs 3272 00 000 Water heater BaltGaz NEVA 4511 1 3251 00 000 01 RE User s manual 1 3272 10 000 Package 1 3208 06 600 Mounting hardware set 1 Spare parts 3103 00 014 Laying D19xd10...

Страница 6: ...appliance d To turn the knobs 1 and 2 to the position of minimal water and gas consumption scheme 5 e To open the hot water tap at this moment electric sparks must appear between the ignition plug and...

Страница 7: ...emperature increase Note 2 Water heating temperature is limited by the appliance s heating effect at big water consumption especially in winter time water at the appliance s outlet may have unsufficie...

Страница 8: ...ng In case if after switching the appliance off water freezing is possible in it it is necessary to drain the water out of the appliance in the following way Close the gas lock valve and cold water lo...

Страница 9: ...appliance Make sure that there is no smell of gas in the premise in case of gas smell detection call the gas facility emergency service 4 1 2 After igniting the main burner it is necessary to visually...

Страница 10: ...d the smoke exhauster is air tight In ordert to provide correct operation of the appliance and to keep warranty it is necessary to fulfill the requirements of this manual 7 INSTALLATION OF THE APPLIAN...

Страница 11: ...ible Also in order to effect maintenance service at the appliance s installation it is necessary to keep the following spacings The distance from the side surface of the appliance to the side wall mus...

Страница 12: ...ppliance s stable operation it is necessary to effect the gas pipeline connection with metal pipes or flexible hoses with inner diameter not less than 13 m The flexible hose for gas inlet in accordanc...

Страница 13: ...is recommended to Use angle joints and adapters in order to avoid the hoses bending next to the tips Use intermediate bearers when installing long hoses In case of linear position install the hoses w...

Страница 14: ...rom the appliance must be not less than 500 mm Gas flue pipe s length from the vertical section to the smoke exhauster must be not less than 2 m Gas flue pipe must have a slope of not less than 2 upwa...

Страница 15: ...nly the branded set of details 7 10 2 In order to reset the appliance to another type and pressure of gas it is necessary to replace the nozzles of the main burner for the nozzles with orifice diamete...

Страница 16: ...ption and increases its temperature The regulator s position also defines water consumption with which switching the appliance on and off occurs see p 3 3 1 8 4 4 Gas consumption regulator 2 regulates...

Страница 17: ...plug 11 flame sensor 12 heat exchanger 13 electromagnetic valve 14 battery section 15 electronic control block 16 thermorelay draught sensor 17 micro switch water flow sensor 18 water temperature sens...

Страница 18: ...valve 14 battery section 15 electronic control block 16 thermorelay draught sensor 17 micro switch 18 water temperature sensor 19 thermorelay water overheating sensor 20 water drain plug 21 gas pressu...

Страница 19: ...sence of air in gas pipelines See note p 3 2 The electromagnetic valve is out of service or the contacts of its connection are disrupted Replace the electromagnetic valve or restore the contacts The e...

Страница 20: ...organization for the appliance s repair The works are effectuated by a specialized service organization 10 GENERAL GUIDELINES 10 1 The installation of gas appliances for domestic use must be effectuat...

Страница 21: ...ened with a neutral detergent and then with a dry wiper 12 2 2 It is prohibited to use detergents of heightened effect and containing abrasive particles gasoline and other organic solvents for cleanin...

Страница 22: ...l service of the appliance At the burner s normal operation the flame must be blue Unscheduled cleaning of the appliance must necessarily be effectuated also in case if in the premise where the applia...

Страница 23: ...he thermorelay 22 screwing off the yoke screws 25 13 7 3 Screw out the hot water temperature sensor 30 together with the ring 31 13 7 4 Screw out two screws connecting the tap of the pipe 8 to the car...

Страница 24: ...ew battery section 13 14 Replacement of electromagnetic valve of the gas tight shaft seal 13 14 1 Remove the casing see p 13 1 13 14 2 Disconnect three wires from the electromagnetic valve 16 of the w...

Страница 25: ...Scheme 18 View of the appliance BaltGaz NEVA 4511 with separated parts...

Страница 26: ...1 12 Display 3227 07 003 1 13 Nozzle of the burner Natural gas G20 2 nd family group 1 3 kPa Natural gas G20 2 nd family group 2 0 kPa Liquiefied gas G30 3 rd family group 2 9 kPa 3295 07 20 005 13 32...

Отзывы: