7.1.5. The appliance must be installed on fire resistant walls - brick-

built, concrete (with ceramic plating or without it). 

7.1.6.It is acceptable to install the appliance on  slow burning walls in 

condition  if  the  wall  is  isolated  by  a  zinc-coated  steel  sheet 

0,8…1 mm 

thick on a sheet of basalt felt woolen board 

3…5 mm. The wall isolation 

must come out of the dimensions of the 

appliance’s casing not less than 

for   100 mm on every side (scheme 8). 

The  distance  from  the  side  surfaces  of  the  appliance  to  the    slow 

burning walls with no usage of isolation must be not less than 250 mm. If  
this  distance  is  reduced  to  150  mm  the  installation  of  heat  insulation  is 
necessary (covering the  walls  with a  zinc-coated steel sheet on a sheet 
of heat insulation material). 

When  installing  the  appliance  on  fire  resistant  walls  the  isolation 

device is not required. 

7.1.7. It  is  prohibited  to  install  the  appliance  on  wooden  walls; 

plastered  walls  with  a  wooden  base,  on  the  walls  covered  with  highly 
flammable materials. 

7.1.8. It is prohibited to install the appliance above a heat source or 

open fire. 

 

Scheme 8. Installing the appliance on 

slow burning walls 

7.1.9. The  place  and  height  of  installation  of  the  appliance  must  provide  the  fulfillment  of  the  requirements  stated  in 

p. 7.7 of this manual.  Herewith it is recommended to install the appliance on such height that the glory-hole would be at the 
customer’s eye level or as close to it as possible. 

Also in order to effect maintenance service at the 

appliance’s installation it is necessary to keep the following spacings: 

The distance from the side surface of the appliance to the side wall must be not less than 150 m; 
Free space by the inlet into the appliance

’s front surface must be not less than 600 mm. 

7.1.10. Scheme  of  the  appliance

’s  installation (putting  it into operation) is shown  on scheme  9. It  is recommended to 

connect the appliance at first to the 

water supply pipeline, to fill the appliance’s system with water and then connect it to the 

gas supply pipeline. 

 

 
                                          

 Cold water inlet   

                                     

Water tap 

                                        Gas outlet pipe                     Cold water  

stop valve 

                                                                                                     

Cold water inlet         Shower device 

                                                                                                      Gas pipeline stop       Water tap 

Valve                     Cold water inlet 
Gas inlet  

Sink

 

                                                   

  Cold water outlet             Water filter                         Bath 

  

Scheme 9. 

The appliance’s installation scheme  

7.2. Mounting the appliance 

7.2.1. Before mounting the appliance it is recommended to remove the casing, for this it is necessary to do the following: 
а)  To remove the knobs 1 and 2 (see scheme 1, 2), pulling them toward yourself;  
б)  to screw out two casing fixation screws on the appliance’s bottom part (see scheme 12, 14); 
в)  to disconnect the wires, connecting the display with the electronic control block and the water temperature sen-

sor;  

г)  to pull the casing’s bottom part towards yourself, move it upwards and remove from the appliance;  
If  the  appliance

’s casing or rear wall is covered with a protective  polythene film, the protective film must be removed 

before the appliance’s installation. Also it is necessary to remove stickers with warning or advertising information from the 
casing

’s  front surface (if there are any) 

Содержание NEVA-4511

Страница 1: ...ment Ltd The telephone number of the unified technical support Service is 8 800 555 40 35 free call on the territory of Russian Federation working hours of the service twenty four hour The installatio...

Страница 2: ...ance 15 7 10 Rendering the appliance to another type and pressure of gas 15 8 CONSTRUCTION AND OPERATION CONTROL OF THE APPLIANCE 15 8 1 Construction of the appliance BaltGaz NEVA 4511 15 8 4 Operatio...

Страница 3: ...fore the failure is eliminated 1 4 In case of the appliance s normal operation and in case if the gas pipeline is failure free there must not be the smell of gas in the premise IN CASE IF YOU FEEL THE...

Страница 4: ...2 2 6 Rated gas pressure kPa mm w g natural G20 2 nd family group liquefied G30 3 rd family group 1 3 130 2 0 200 2 9 300 2 2 7 Rated gas consumption natural m 3 h liquefied kg h 2 2 1 66 2 2 8 Rated...

Страница 5: ...nation Name Quantity pcs 3272 00 000 Water heater BaltGaz NEVA 4511 1 3251 00 000 01 RE User s manual 1 3272 10 000 Package 1 3208 06 600 Mounting hardware set 1 Spare parts 3103 00 014 Laying D19xd10...

Страница 6: ...appliance d To turn the knobs 1 and 2 to the position of minimal water and gas consumption scheme 5 e To open the hot water tap at this moment electric sparks must appear between the ignition plug and...

Страница 7: ...emperature increase Note 2 Water heating temperature is limited by the appliance s heating effect at big water consumption especially in winter time water at the appliance s outlet may have unsufficie...

Страница 8: ...ng In case if after switching the appliance off water freezing is possible in it it is necessary to drain the water out of the appliance in the following way Close the gas lock valve and cold water lo...

Страница 9: ...appliance Make sure that there is no smell of gas in the premise in case of gas smell detection call the gas facility emergency service 4 1 2 After igniting the main burner it is necessary to visually...

Страница 10: ...d the smoke exhauster is air tight In ordert to provide correct operation of the appliance and to keep warranty it is necessary to fulfill the requirements of this manual 7 INSTALLATION OF THE APPLIAN...

Страница 11: ...ible Also in order to effect maintenance service at the appliance s installation it is necessary to keep the following spacings The distance from the side surface of the appliance to the side wall mus...

Страница 12: ...ppliance s stable operation it is necessary to effect the gas pipeline connection with metal pipes or flexible hoses with inner diameter not less than 13 m The flexible hose for gas inlet in accordanc...

Страница 13: ...is recommended to Use angle joints and adapters in order to avoid the hoses bending next to the tips Use intermediate bearers when installing long hoses In case of linear position install the hoses w...

Страница 14: ...rom the appliance must be not less than 500 mm Gas flue pipe s length from the vertical section to the smoke exhauster must be not less than 2 m Gas flue pipe must have a slope of not less than 2 upwa...

Страница 15: ...nly the branded set of details 7 10 2 In order to reset the appliance to another type and pressure of gas it is necessary to replace the nozzles of the main burner for the nozzles with orifice diamete...

Страница 16: ...ption and increases its temperature The regulator s position also defines water consumption with which switching the appliance on and off occurs see p 3 3 1 8 4 4 Gas consumption regulator 2 regulates...

Страница 17: ...plug 11 flame sensor 12 heat exchanger 13 electromagnetic valve 14 battery section 15 electronic control block 16 thermorelay draught sensor 17 micro switch water flow sensor 18 water temperature sens...

Страница 18: ...valve 14 battery section 15 electronic control block 16 thermorelay draught sensor 17 micro switch 18 water temperature sensor 19 thermorelay water overheating sensor 20 water drain plug 21 gas pressu...

Страница 19: ...sence of air in gas pipelines See note p 3 2 The electromagnetic valve is out of service or the contacts of its connection are disrupted Replace the electromagnetic valve or restore the contacts The e...

Страница 20: ...organization for the appliance s repair The works are effectuated by a specialized service organization 10 GENERAL GUIDELINES 10 1 The installation of gas appliances for domestic use must be effectuat...

Страница 21: ...ened with a neutral detergent and then with a dry wiper 12 2 2 It is prohibited to use detergents of heightened effect and containing abrasive particles gasoline and other organic solvents for cleanin...

Страница 22: ...l service of the appliance At the burner s normal operation the flame must be blue Unscheduled cleaning of the appliance must necessarily be effectuated also in case if in the premise where the applia...

Страница 23: ...he thermorelay 22 screwing off the yoke screws 25 13 7 3 Screw out the hot water temperature sensor 30 together with the ring 31 13 7 4 Screw out two screws connecting the tap of the pipe 8 to the car...

Страница 24: ...ew battery section 13 14 Replacement of electromagnetic valve of the gas tight shaft seal 13 14 1 Remove the casing see p 13 1 13 14 2 Disconnect three wires from the electromagnetic valve 16 of the w...

Страница 25: ...Scheme 18 View of the appliance BaltGaz NEVA 4511 with separated parts...

Страница 26: ...1 12 Display 3227 07 003 1 13 Nozzle of the burner Natural gas G20 2 nd family group 1 3 kPa Natural gas G20 2 nd family group 2 0 kPa Liquiefied gas G30 3 rd family group 2 9 kPa 3295 07 20 005 13 32...

Отзывы: