background image

 

the  water heater on occurs at water consumption not less than  2,5 l/min, at the  knob position at 

“Maximum consump-

tion

 

– at water consumption not less than 6 l/min. In the in-between positions of the knob 1 switching the water heater 

on occurs, respectively, in the consumption range not less than 2,5...6 l/min. 

At reduced inlet water pressure (at small water consumption provided by the water supply pipeline) for switching the 

appliance on it is recommended to leave the appliance’s knob 1 in the position 

“Minimal consumption”

. In this position it 

is possible to receive small and middle hot water consumption (2,5...5 l/min) by the outlet from the appliance. In order to 
receive big amount of warm water  by the appliance

’s outlet at normal inlet water pressure (if consumption of 6 l/min and 

more is provided by the water supply pipeline) the knob 1 should be switched to the position 

“Maximum consumption”

 

 

 

а) 

Water consumption regulation knob 1 and gas 

consumption regulation knob 2 in the position 

“Minimal consumption”

 

b) Water consumption regulation knob 1 and gas 

consumption regulation knob 2 in the position 

“Maximum consumption”

 

Scheme 4. The appliance 

«BaltGaz NEVA-4511»’s regulation knobs’ position  

Note 1.

 At small consumption of water going through the appliance that is in operation, turning the knob 1 to the posi-

tion 

“Maximum consumption” 

 may 

lead to the burner’s flame failure. The burner’s flame failure is possible also in case 

of reducing the consumption by the hot water tap or at reduction of the inlet water pressure. In order to put the burner into 
operation again, it is necessary to turn the knob 1 to the position 

“Minimal Consumption”

 or to increase water consump-

tion by the hot water tap. 

3.3.2.  Water temperature regulation through the appliance at its fixed consumption rate is effectuated by turning the 

gas consumption regulation knob 2 (scheme13,14): turning the knob into the position 

“Maximum consumption” increases 

gas consumption and water 

temperature at the appliance’s outlet, turning the knob to the position “Minimal consumption” 

reduces gas consumption and water temperature at the a

ppliance’s outlet. 

It  is  also  possible  to  regulate  water  temperature  by  the  appliance

’s outlet by changing water consumption with hot 

water  tap  or  knob  1: 

water  consumption  increase  leads  to  its  temperature’s  reduction,  and  on  the  contrary  water  con-

sumption reduction leads to its temperature increase. 

Note 2. 

Water heating temperature is limited by the appliance

’s heating effect: at big water consumption, especially 

in winter time, water at the appliance

’s outlet may have unsufficient temperature even at maximum gas consumption. In 

this case in order to increase water temperature it is necessary to reduce the consumption of the water going through the 
water heater.  

Water temperature at the appliance

’s outlet is shown on the two-digit digital display installed on  the decorative trim 

on the appliance’s casing. 

Note 3.

 At small water consumption (with knob 1 in the position 

“Minimal consumption”

) and big gas consumption 

(with knob 2 in the position  

“Maximum consumption”

) water overheating in the heat exchanger is possible and conse-

quently the burner might be switched off by the authomatic control system of the appliance. In order to switch the appli-
ance on once again it is necessary to close the hot water tap and then to open it once again. In order not to let the water 
overheating occur it is necessary to reduce gas consumption with the knob 2 or to increase consumption of water going 
through the appliance with knob 1 or hot water tap.   

Water overheating in the heat exchanger leads to appearance of noise during the appliance

’s operation and causes 

quick appearance of scale deposit in the pipes of the heat exchanger and narrowing of their clear opening what eventual-
ly 

leads to the appliance’s operation efficiency reduction and diminution of hot water current. So in order to reduce the 

temperature of water coming out of the appliance it is not recommended, especially in case of hard water, to use the mix-
er tap adding cold water, but it is recommended to use the above-listed methods.In order to reduce scale deposit appear-
ance  intensity

 

it  is  recommended  to  prevent  water  heating    at  the  appliance’s  outlet  for  more  than   

60

С.  

3.4. Switching the appliance off 

After finishing the appliance

’s usage (at nighttime, when not being at home etc.) it must be switched off. In order to 

switch the appliance off it is enough to stop water flowing through it by closing all  hot water taps, after this it is necessary 
to make sure that the flame of the burner has completely  gone out. 

 

ATTENTION

!

  In  case  if  after  closing  all  hot  water  taps  the  main  burner  continues  operating  it  is  necessary 

to: 

 

Immediately  shut the gas supply off with the gas stop valve installed by the inlet into the ap-
pliance. 

Then it is necessary to call the specialized service 

organization for the appliance’s repair.  

3.5. 

Changing the batteries of the appliance «BaltGaz NEVA-4511» 

 

Содержание NEVA-4511

Страница 1: ...ment Ltd The telephone number of the unified technical support Service is 8 800 555 40 35 free call on the territory of Russian Federation working hours of the service twenty four hour The installatio...

Страница 2: ...ance 15 7 10 Rendering the appliance to another type and pressure of gas 15 8 CONSTRUCTION AND OPERATION CONTROL OF THE APPLIANCE 15 8 1 Construction of the appliance BaltGaz NEVA 4511 15 8 4 Operatio...

Страница 3: ...fore the failure is eliminated 1 4 In case of the appliance s normal operation and in case if the gas pipeline is failure free there must not be the smell of gas in the premise IN CASE IF YOU FEEL THE...

Страница 4: ...2 2 6 Rated gas pressure kPa mm w g natural G20 2 nd family group liquefied G30 3 rd family group 1 3 130 2 0 200 2 9 300 2 2 7 Rated gas consumption natural m 3 h liquefied kg h 2 2 1 66 2 2 8 Rated...

Страница 5: ...nation Name Quantity pcs 3272 00 000 Water heater BaltGaz NEVA 4511 1 3251 00 000 01 RE User s manual 1 3272 10 000 Package 1 3208 06 600 Mounting hardware set 1 Spare parts 3103 00 014 Laying D19xd10...

Страница 6: ...appliance d To turn the knobs 1 and 2 to the position of minimal water and gas consumption scheme 5 e To open the hot water tap at this moment electric sparks must appear between the ignition plug and...

Страница 7: ...emperature increase Note 2 Water heating temperature is limited by the appliance s heating effect at big water consumption especially in winter time water at the appliance s outlet may have unsufficie...

Страница 8: ...ng In case if after switching the appliance off water freezing is possible in it it is necessary to drain the water out of the appliance in the following way Close the gas lock valve and cold water lo...

Страница 9: ...appliance Make sure that there is no smell of gas in the premise in case of gas smell detection call the gas facility emergency service 4 1 2 After igniting the main burner it is necessary to visually...

Страница 10: ...d the smoke exhauster is air tight In ordert to provide correct operation of the appliance and to keep warranty it is necessary to fulfill the requirements of this manual 7 INSTALLATION OF THE APPLIAN...

Страница 11: ...ible Also in order to effect maintenance service at the appliance s installation it is necessary to keep the following spacings The distance from the side surface of the appliance to the side wall mus...

Страница 12: ...ppliance s stable operation it is necessary to effect the gas pipeline connection with metal pipes or flexible hoses with inner diameter not less than 13 m The flexible hose for gas inlet in accordanc...

Страница 13: ...is recommended to Use angle joints and adapters in order to avoid the hoses bending next to the tips Use intermediate bearers when installing long hoses In case of linear position install the hoses w...

Страница 14: ...rom the appliance must be not less than 500 mm Gas flue pipe s length from the vertical section to the smoke exhauster must be not less than 2 m Gas flue pipe must have a slope of not less than 2 upwa...

Страница 15: ...nly the branded set of details 7 10 2 In order to reset the appliance to another type and pressure of gas it is necessary to replace the nozzles of the main burner for the nozzles with orifice diamete...

Страница 16: ...ption and increases its temperature The regulator s position also defines water consumption with which switching the appliance on and off occurs see p 3 3 1 8 4 4 Gas consumption regulator 2 regulates...

Страница 17: ...plug 11 flame sensor 12 heat exchanger 13 electromagnetic valve 14 battery section 15 electronic control block 16 thermorelay draught sensor 17 micro switch water flow sensor 18 water temperature sens...

Страница 18: ...valve 14 battery section 15 electronic control block 16 thermorelay draught sensor 17 micro switch 18 water temperature sensor 19 thermorelay water overheating sensor 20 water drain plug 21 gas pressu...

Страница 19: ...sence of air in gas pipelines See note p 3 2 The electromagnetic valve is out of service or the contacts of its connection are disrupted Replace the electromagnetic valve or restore the contacts The e...

Страница 20: ...organization for the appliance s repair The works are effectuated by a specialized service organization 10 GENERAL GUIDELINES 10 1 The installation of gas appliances for domestic use must be effectuat...

Страница 21: ...ened with a neutral detergent and then with a dry wiper 12 2 2 It is prohibited to use detergents of heightened effect and containing abrasive particles gasoline and other organic solvents for cleanin...

Страница 22: ...l service of the appliance At the burner s normal operation the flame must be blue Unscheduled cleaning of the appliance must necessarily be effectuated also in case if in the premise where the applia...

Страница 23: ...he thermorelay 22 screwing off the yoke screws 25 13 7 3 Screw out the hot water temperature sensor 30 together with the ring 31 13 7 4 Screw out two screws connecting the tap of the pipe 8 to the car...

Страница 24: ...ew battery section 13 14 Replacement of electromagnetic valve of the gas tight shaft seal 13 14 1 Remove the casing see p 13 1 13 14 2 Disconnect three wires from the electromagnetic valve 16 of the w...

Страница 25: ...Scheme 18 View of the appliance BaltGaz NEVA 4511 with separated parts...

Страница 26: ...1 12 Display 3227 07 003 1 13 Nozzle of the burner Natural gas G20 2 nd family group 1 3 kPa Natural gas G20 2 nd family group 2 0 kPa Liquiefied gas G30 3 rd family group 2 9 kPa 3295 07 20 005 13 32...

Отзывы: