www.balluff.com
53
english
Statistics Data Output: Status
Bit
position
Meaning
Description
0
Configured
1 – all inputs are configured
1
Started min/
max/avg
1 – min/max/avg running
2
Started moving
average
1 – moving average
running
3
Buffer Overflow
Event
1 – buffer overflow
4
Timeout Event
1 – the set time for the
minimum value/maximum
value/average calculation
has elapsed
5
Reserved
–
6
Reserved
–
7
Reserved
–
Tab. 5-26: Statistics Data Output – Status
5.5.5 System Commands
Command Value Device Action
0xA7 (167)
Statistics Reset
– Resets all output
parameters to 0 and all user
settings to the default values.
0xA8 (168)
Statistics Start min/max/avg
–
Starts the statistics of the minimum
value/maximum value/average
calculation.
0xA9 (169)
Statistics Stop
– Stops statistics
operation completely.
0xAC (172)
Statistics Start Moving Average
– Starts the statistics of the moving
average calculation.
Tab. 5-27: Basic statistics – System Commands