![Balluff BVS SC 1280Z00-07-000 Series Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/balluff/bvs-sc-1280z00-07-000-series/bvs-sc-1280z00-07-000-series_user-manual_3604455031.webp)
31
BVS Cockpit
NOTE
After switching on and after switching to another inspection program the outputs are set as
in the general settings:
•
0 V if Inv. is not active
•
24 V if Inv. is active
All logical signals are permanently linked with the physical signals of the plug connectors. I/O 0
and I/O 1 exists twice.
Signal
I/O 0
I/O 1
I/O 2
I/O 3
I/O 4
I/O 5
I/O 6
I/O 7
Power
Pin 2
Pin 4
I/O
Pin 1
Pin 3
Pin 4
Pin 5
Pin 6
Pin 8
I/O Light
Pin 2
Pin 4
If I/O 0 is operated as output, pin 1 at the I/O connection and pin 2 at the power connection are switched.
If the I/Os are configured as input, their signals are logically combined with OR. This means, a 1 signal is recognized if a
1 signal is present either at pin 2 of the power connection or pin 1 of the I/O connection. The same applies to I/O 1.
NOTE
If the pulse length exceeds the throughput time for an inspection this may result in unde-
sired effects.