![Balluff BVS SC 1280Z00-07-000 Series Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/balluff/bvs-sc-1280z00-07-000-series/bvs-sc-1280z00-07-000-series_user-manual_3604455015.webp)
15
BVS Cockpit
3.3.4
Operating conditions
Ambient temperature
0 °C to +55 °C
Storage temperature
–25 °C to +70 °C
EMC
EMV EN 61000-4-2/3/4/5/6
EN 61000-6-2
EN 61000-6-3
EN 55011
Vibration/shock for operation in-
side
EN 60068 Part 2-6/27
Operation
Internally
Height
up to 2000 m
Relative humidity
maximum 80 % for temperatures up to 31 °C, decreasing linearly to 50 % at
40 °C
Pollution degree
Pollution degree 2
Vibration/shock was verified for the
SMARTCAMERA
– the C-mount lens used and its adjustment rings must be secured
accordingly for operation.
3.4 Connections and pin assignment
The product variants differ by the existing interfaces.
3.4.1
I/O variant
Connection
Function
Power
Voltage supply of
SMARTCAMERA
, wo freely configurable I/O signals are also available.
LAN
Integrates the
SMARTCAMERA
in a local network.
I/O
To connect sensors/actuator, 6 galvanically isolated I/O signals are available.
I/O Light
2 I/O signals and supply voltage output, e.g. for an external lighting
ATTENTION
Risk of equipment damage
The
SMARTCAMERA
and accessories shall be supplied by limited energy in accordance to
UL 61010-1 Third Edition, Sub. Clauses 9.4 or LPS in accordance to UL 60950-1 or Class 2
in accordance to UL 1310 or UL 1585.
NOTE
In order to ensure enclosure rating IP67, unused I/O ports must be closed with cover caps.