![Balluff BVS SC 1280Z00-07-000 Series Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/balluff/bvs-sc-1280z00-07-000-series/bvs-sc-1280z00-07-000-series_user-manual_3604455019.webp)
19
BVS Cockpit
Output connection
If I/O 0 is configured as output, the supply voltage is applied at the output and the actuator, PLC input is supplied with it if
1 is being output. The output is connected with GND if 0 is being output. The output current of an I/O may not exceed
100 mA.
If the output is being overloaded, e.g. by a short circuit, it is switched off and periodically checked whether the fault oc-
currence is still present. If the error was removed, the output is again in normal operating state without a reset.
PNP output connection
PNP logic is predominantly used in Europe. The output is sourcing, so that the load between I/O and GND must be
switched accordingly. The load is connected with supply voltage if 1 is being output.
NPN-Ausgangsbeschaltung
NPN logic is predominantly used in Asia. The output is sinking, so that the load between I/O and supply voltage must be
switched accordingly. The load is set to GND if 0 is being output.
To obtain a normal switching behavior, the output can be inverted.
3.4.3
LAN
The LAN interface meets the Ethernet standard in accordance with IEEE 802.3-2008 (up to 1 Gigabit). This network con-
nection is used to call up the web interface BVS Cockpit for the configuration. In addition, a communication channel is
available to control the image analysis and to call up the generated result values.