Balluff BVS SC 1280Z00-07-000 Series Скачать руководство пользователя страница 19

www.balluff.com

 

 

19

 

BVS Cockpit

 

 

Output connection 

If I/O 0 is configured as output, the supply voltage is applied at the output and the actuator, PLC input is supplied with it if 
1 is being output. The output is connected with GND if 0 is being output. The output current of an I/O may not exceed 
100 mA. 

If the output is being overloaded, e.g. by a short circuit, it is switched off and periodically checked whether the fault oc-
currence is still present. If the error was removed, the output is again in normal operating state without a reset. 

PNP output connection 

PNP logic is predominantly used in Europe. The output is sourcing, so that the load between I/O and GND must be 
switched accordingly. The load is connected with supply voltage if 1 is being output. 

 

NPN-Ausgangsbeschaltung 

NPN logic is predominantly used in Asia. The output is sinking, so that the load between I/O and supply voltage must be 
switched accordingly. The load is set to GND if 0 is being output. 

To obtain a normal switching behavior, the output can be inverted. 

 

3.4.3 

LAN 

The LAN interface meets the Ethernet standard in accordance with IEEE 802.3-2008 (up to 1 Gigabit). This network con-
nection is used to call up the web interface BVS Cockpit for the configuration. In addition, a communication channel is 
available to control the image analysis and to call up the generated result values. 

 

Содержание BVS SC 1280Z00-07-000 Series

Страница 1: ...BVS SC _1280Z00 07 000 SMARTCAMERA IO...

Страница 2: ......

Страница 3: ...2 3 Operation 9 2 2 4 Maintenance inspection repair 9 2 3 Disposal 10 3 PRODUCT DESCRIPTION 11 3 1 Product variants 11 3 2 Scope of delivery 12 3 2 1 Assembly 13 3 3 Product specification 14 3 3 1 Im...

Страница 4: ...3 System settings 29 5 4 Selecting the communication interface for the process data 29 5 5 Network settings LAN interface 30 5 5 1 Network configuration via BVS Cockpit 30 5 6 Digital I O interface 30...

Страница 5: ...mera access from the network Simple and user friendly settings control of camera without additional software Simple user supporting operation Support of Industry 4 0 through Integrated flexible displa...

Страница 6: ...RC_16 1 3 5 Directory paths Path information for saving data is shown with fixed font width e g Projekt Data Types Benutzerdefin iert 1 3 6 ASCII code Characters transmitted in ASCII code are set in a...

Страница 7: ...tic compatibility EtherNet IP Ethernet Industrial Protocol FCC Federal Communications Commission FE Function ground GND Ground I O port Digital input output port ID Identification IO Input Output IP I...

Страница 8: ...f Enduser Licensing Agreement You may use the software only in compliance with these provisions If they should not yet be available Balluff GmbH will gladly provide the current GTC upon request The SM...

Страница 9: ...ernal controller observe proper selec tion and polarity of the connection as well as the power supply see Connections and pin assignment The SMARTCAMERA may only be used with an approved power supply...

Страница 10: ...ervention in the product by the operator is not permitted due to safety reasons The SMARTCAMERA s housing may not be opened or loosened NOTE In the interests of product improvement Balluff GmbH reserv...

Страница 11: ...uired for the configura tion and monitor display Using standardized web browsers such as Google Chrome Mozilla Firefox or Internet Explorer the user can easily connect with the SMARTCAMERA and work in...

Страница 12: ...s in accordance with IP67 NOTE Only C mount lenses with a maximum diameter of 42 mm and a length of 40 mm can be used here For lenses up to 69 mm the long tube BAM PC VS 023 1 01 BAM02W0 may be used F...

Страница 13: ...he following drawings describe the exact position of all mounting holes Individual threads are also used for fastening optional accessories see chapter Accessories The screw connections at the rear pl...

Страница 14: ...inted aluminum die cast box Degree of protection IP67 with connectors and protection tube 2 Weight approx 360 g Dimensions L W H without connector without lens 110 62 55 mm 2 The enclosure rating has...

Страница 15: ...nections and pin assignment The product variants differ by the existing interfaces 3 4 1 I O variant Connection Function Power Voltage supply of SMARTCAMERA wo freely configurable I O signals are also...

Страница 16: ...odule must not ex ceed 4 A per pin The load or supply must be limited accordingly LAN 8 pin M12 socket X coded Pin Description Function 1 BI_DA Bidirectional data Pair A 2 BI_DA Bidirectional data Pai...

Страница 17: ...put output 5 Not used None Pin may not be used NOTE These inputs outputs are galvanically decoupled from the supply voltage of the SMARTCAMERA For this reason Common In and Common out must always be c...

Страница 18: ...ype 3 Below are examples how inputs and outputs must be connected to obtain input and output function NOTE These inputs outputs are galvanically decoupled from the supply voltage of the SMARTCAMERA Fo...

Страница 19: ...ominantly used in Europe The output is sourcing so that the load between I O and GND must be switched accordingly The load is connected with supply voltage if 1 is being output NPN Ausgangsbeschaltung...

Страница 20: ...oltage drop VD 2 V Delay 0 1 10 s 1 0 10 s Supply voltage output Voltage VP 24 V VDC VD 1 2 A max Voltage dropVD 2 V Among other things this makes it possible to easily connect lighting equipment to t...

Страница 21: ...zu VCommon In 2 to 8 mA Delay 0 1 70 s 1 0 150 s Operation as output PNP NPN Voltage Signal 0 High resistance High resistance 100 mA max Signal 1 24 V VCommon Out VD 0 V VCommon Out VD 100 mA max Volt...

Страница 22: ...set to Common In or is not connected If I O 0 is configured as output the output is connected with Common Out and the actuator PLC input or similar is sup plied with it if 1 is being output The outpu...

Страница 23: ...o Common In or is not connected If I O 0 is configured as output the output is connected with Common Out and the actuator PLC input or similar is sup plied with it if 1 is being output The output is h...

Страница 24: ...or a trigger Green flashing Inspection stopped or in configuration mode Red on Fault Red flashing Firmware update active Signal LED Off Signal 0 Yellow on Signal 1 The signal LED indicates the status...

Страница 25: ...uctures are possible Structure Consequences SMARTCAMERA and PC are in the same subnet of a local network and no DHCP server is available for automatic IP assignment In this case the IP addresses of PC...

Страница 26: ...40 and above NOTE JavaScript must be enabled in the web browser 1 Record the serial number of the SMARTCAMERA The serial number is located on the nameplate on the SMARTCAMERA If the nameplate is not v...

Страница 27: ...website www balluff com and save it on your computer 2 Unzip the downloaded file It contains a A PDF document that describes the new functions fixed errors and the update procedure b The file BVS_Coc...

Страница 28: ...his covers a large part of the application cases To operate the SMARTCAMERA re quires that the supply voltage is provided via the power connection in any case The IO1 topology shows a simply design wi...

Страница 29: ...tem 5 4 Selecting the communication interface for the process data The exchange of the process data results of image analysis control of image acquisition are exchanged via the LAN interface using TCP...

Страница 30: ...in the net work 5 6 Digital I O interface The SMARTCAMERA provides eight internal I O signals Digital inputs and outputs are configured in the System settings on the Digital inputs outputs tab Settin...

Страница 31: ...4 I O 5 I O 6 I O 7 Power Pin 2 Pin 4 I O Pin 1 Pin 3 Pin 4 Pin 5 Pin 6 Pin 8 I O Light Pin 2 Pin 4 If I O 0 is operated as output pin 1 at the I O connection and pin 2 at the power connection are sw...

Страница 32: ...Set the IP address to automatically 3 Inside the tab alternative configuration also set the IP address to autmatically 4 Close the windows and restart the PC 5 Retry the previously described way No co...

Страница 33: ...1 Change to the action menu Configuration 2 Select the Tool Get image 3 Deactivate the checkbox outImage in the result ta ble 4 Repeat this step for every used Get image and Find object tool Not ever...

Страница 34: ...lenses up to a length of 86 mm C mount lenses BAMXXXX BAM LS VS xxx C2 3 xxxx x C mount lens Filters BAMXXXX BAM OF VS 002 xx xx Lens filter 27 mm Spacer rings BAM02MT BAM SP XO 002 0 5 40 31 A C Mou...

Страница 35: ...No EN 08 131532 G21 Subject to modification Replaces G20...

Отзывы: