BTL5-T1_ _-M_ _ _ _-A/B/Y/Z-S103
Micropulse Linear Transducer - Rod Style
9
english
6
Startup
6.1
Check connections
Although the connections are po-
larity reversal protected, compo-
nents can be damaged by im-
proper connections and overvolt-
age. Before you apply power,
check the connections carefully.
6.2
Turning on the system
Note that the system may execute
uncontrolled movements when first
turned on or when the transducer is
part of a closed-loop system whose
parameters have not yet been set.
Therefore make sure that no haz-
ards could result from these situa-
tions.
6.3
Check output values
After replacing or repairing a trans-
ducer, it is advisable to verify the
values for the start and end position
of the magnet in manual mode. If
values other* than those present
before the replacement or repair are
found, a correction should be made.
* Transducers are subject to modifi-
cation or manufacturing tolerances.
6.4
Check functionality
The functionality of the transducer
system and all its associated
components should be regularly
checked and recorded.
6.5
Fault conditions
When there is evidence that the
transducer system is not operating
properly, it should be taken out of
service and guarded against unau-
thorized use.
7
Versions (indicated on part label)
Supply voltage
: 1 = DC 24 V
Electr. connection
:
Type: BTL5-T110-M1000-B-S103
S103 = 1 × 3-pin male
1 × 5-pin male
1 × 5-pin female
Rod Style,
Mounting: A / B = metric thread M18×1.5
Y / Z = Thread 3/4"-16UNF
Nominal stroke (4 digits
): M =
Metric units [mm]
Type No. of magnets
1
1 - 4 selectable using GSD
Ordering code: BTL_ _ _ _
Micr
opulse W
egaufnehmer
PROFIBUS-DP-Schnittstelle
7.1
Available stroke lengths
and magnets
Nominal stroke lengths from 25 to
4000 mm are available for ideally
sizing the transducer to the appli-
cation.
7.2
Included in shipment
Transducer with condensed guide
➥
➥
➥
➥
➥
Fig. 3-1
7.3
Software
Download the GSD file from
www.balluff.de
..... or via e-mail