www.balluff.com
47
english
6.4.6 Events
Event Code
Event Type
Description
Device Status
0x8D07 (36103)
Warning
The calculation of the basic statistics was stopped
automatically to avoid a buffer overflow.
0 – Device is
operating properly.
0x8D0E (36110)
Notification
The time has elapsed. This event reports the timeout of
the minimum value/maximum value/average calculation.
It does not report a timeout for the calculation of the
moving average because the timer repeats and it does
not indicate the end of the calculation.
0 – Device is
operating properly.
Tab. 6-28: Basic statistics – Events
6.4.7 Variant Dependence
The functionality is available in all variants.
6
Secondary Device Functions (continued)
BOS R254K-UUI-LS10-S4
Photoelectric Sensors
Содержание BOS R254K-UUI-LS10-S4
Страница 1: ...deutsch Konfigurationsanleitung english Configuration Guide BOS R254K UUI LS10 S4 ...
Страница 2: ...www balluff com ...
Страница 3: ...BOS R254K UUI LS10 S4 Konfigurationsanleitung deutsch ...
Страница 4: ...www balluff com ...
Страница 88: ......
Страница 89: ...BOS R254K UUI LS10 S4 Configuration Guide english ...
Страница 90: ...www balluff com ...