40
english
Switching Counter Input
With
Switching Counter Input
, the internal binary signal
source can be selected.
Input
contains a list of the internal
binary signals.
Value
Meaning
0x0002 (2)
Digital Input Pin 2
0x0003 (3)
Switching Counter Limit not reached
0x0004 (4)
Switching Counter Limit reached
0x0005 (5)
Switching Counter Limit exceeded
0x0007 (7)
Switching Counter Reset
0x0008 (8)
Signal Delay Channel 1
0x0009 (9)
Signal Delay Channel 2
0x000A (10)
Signal Delay Channel 3
0x000B (11)
Signal Delay Channel 4
0x0010 (16)
Switching Speed ok
0x0011 (17)
Switching Speed Too Low
0x0012 (18)
Switching Speed Too High
0x0014 (20)
Switching Speed Reset
0x0015 (21)
Short Circuit Pin 4
0x0016 (22)
Short Circuit Pin 2
0x0017 (23)
Undervoltage
0x0018 (24)
Overvoltage
0x0023 (35)
Humidity Bad
0x0027 (39)
Transducer Enable
0x002D (45)
Optical Transmitter Error
0x002F (47)
System Error
0x0034 (52)
PDout Invalid
0x0037 (55)
Inclination Alarm Status
0x0041 (65)
Lifetime Extreme
0x004B (75)
Vibration Alarm Status
0x004E (78)
Temperature Status Customer Limits
0x004F (79)
Temperature Status Device Limits
0x0063 (99)
Logic block result 1
0x0064 (100)
Logic block result 2
0x0065 (101)
Logic block result 3
0x0066 (102)
Logic block result 4
Tab. 6-16: Switching Counter Input
6
Secondary Device Functions (continued)
Switching Counter Mode
With
Switching Counter Mode
, the current mode of the
counter function can be selected.
Value
Meaning
Description
0x00 (0) Deactivated
Deactivated
0x01 (1) Static
Static counter function
0x02 (2) Auto
Auto counter function
Tab. 6-17: Switching Counter – Switching Counter Mode
Switching Counter Limit
With
Switching Counter Limit
, the count limit for the
counter can be set. The value range is between 0x0002 (2)
and 0xFFFF (65535).
Switching Counter Startup Delay
With
Switching Counter Startup Delay
, the time for the
startup delay can be set. The startup delay begins after the
supply voltage is switched on. During the startup delay,
the counter has no function. The counter starts after the
startup delay has elapsed. The value represents the time in
seconds. The value range is between 0x00 (0) and 0xFF
(255). A value of 0x00 (0) represents no start delay.
Switching Counter State
With
Switching Counter State
, the current status can be
read.
Value
Meaning
Description
0x00 (0) Not reached
Value
is less than
Limit
.
0x01 (1) reached
Value
is greater than or equal to
Limit
.
0x03 (3) exceeded
Value
is greater than
Limit
.
0x08 (8) Startup
Delay
Startup delay currently running.
0xFF
(255)
Deactivated
Feature is deactivated.
Tab. 6-18: Switching Counter – Switching Counter State
Switching Counter Value
With
Switching Counter Value
, the current counter value
can be read.
BOS R254K-UUI-LS10-S4
Photoelectric Sensors
Содержание BOS R254K-UUI-LS10-S4
Страница 1: ...deutsch Konfigurationsanleitung english Configuration Guide BOS R254K UUI LS10 S4 ...
Страница 2: ...www balluff com ...
Страница 3: ...BOS R254K UUI LS10 S4 Konfigurationsanleitung deutsch ...
Страница 4: ...www balluff com ...
Страница 88: ......
Страница 89: ...BOS R254K UUI LS10 S4 Configuration Guide english ...
Страница 90: ...www balluff com ...