74
english
7.4
Variant Configuration
After a variant changeover, an inconsistent
configuration may occur because there is no
automatic changeover of parameters.
It is therefore recommended that the setup be
done in the following order:
1.
Variant setting
2.
Perform factory reset or set valid parameters.
7.4.1 Description
Allows switching between different process data profiles.
7.4.2 ISDU
Name
Index
Subindex
Access
Length
Data Type
Data Storage
Default
Device Variant
0x0055 (85)
0
R/W
2 bytes
UINT16(ENUM)
No
0x0003 (3)
Tab. 7-10: Variant Configuration – ISDU
Device Variant
This parameter indicates which variant is currently set. The
device variant can be changed either with this parameter
or by using the IO-Link compatibility mode. If this
parameter is written, the device variant is not changed
immediately but instead after the device is restarted. If the
device variant is changed via the IO-Link compatibility
mode, the change in this parameter is visible immediately.
This parameter is not changed by a reset.
The following device variants are available:
Value
Meaning
Description
0x0003 (3)
CM
Condition Monitoring
0x0004 (4)
CNT
Counter
0x0005 (5)
CCM
Comprehensive Condition Monitoring
Tab. 7-11: Overview of device variants
7
System Functions (continued)
BOS R254K-UUI-LS10-S4
Photoelectric Sensors
Содержание BOS R254K-UUI-LS10-S4
Страница 1: ...deutsch Konfigurationsanleitung english Configuration Guide BOS R254K UUI LS10 S4 ...
Страница 2: ...www balluff com ...
Страница 3: ...BOS R254K UUI LS10 S4 Konfigurationsanleitung deutsch ...
Страница 4: ...www balluff com ...
Страница 88: ......
Страница 89: ...BOS R254K UUI LS10 S4 Configuration Guide english ...
Страница 90: ...www balluff com ...